{"product_id":"1012-925c-furnace-control-board-24-vac-hsi-compatible-rheem-ruud","title":"1012-925C Furnace Control Board 24 VAC HSI Compatible with Rheem Ruud","description":"\u003ch2\u003e1012-925C Furnace Control Board 24 VAC HSI Compatible with Rheem Ruud\u003c\/h2\u003e\n\u003cp\u003eThe 1012-925C integrated furnace control is engineered as a direct replacement board for gas furnaces running a Rheem, Ruud or Weather King 62-24268 series control. A built-in microprocessor manages hot surface ignition, flame sensing and the heating sequence, cycling the gas valve, inducer and blower, and shutting the gas valve safely if an abnormal condition is detected.\u003c\/p\u003e\n\n\u003ch3\u003e📋 Key Takeaways\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eExact Replacement:\u003c\/strong\u003e Directly replaces the 1012-925C (62-24268-03) integrated furnace control and the earlier 62-24268-02, 62-24268-01 and 62-24192-01 boards, for direct-fit installation.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eBroad Brand Coverage:\u003c\/strong\u003e Compatible with Rheem, Ruud and Weather King gas furnaces that use these 62-24268 series control boards.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eReliable Ignition \u0026amp; Safety:\u003c\/strong\u003e Hot surface ignition with microprocessor flame monitoring — on an abnormal condition the gas valve shuts down safely.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eTransparent Electrical Specs:\u003c\/strong\u003e Runs on standard 24 VAC 50\/60 Hz furnace power with relay control output and under 5 W standby consumption.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eCheck Before You Order:\u003c\/strong\u003e Confirm the part number printed on your old board matches 62-24268-01, 62-24268-02, 62-24268-03 or 62-24192-01 — this board is not a universal fit for other furnace brands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003cth style=\"width: 35%;\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eBenefit (What It Means for You)\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eMicroprocessor Ignition \u0026amp; Sequencing\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eAutomatic hot surface ignition with flame confirmation; manages burner, inducer and blower timing through the heating sequence for dependable winter heating.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eRheem Ruud Weather King Coverage\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eReplaces the 62-24268-03 control plus the earlier 62-24268-02, 62-24268-01 and 62-24192-01 boards used in Rheem, Ruud and Weather King gas furnaces.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003e24 VAC Standard Ratings\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eInput 24 VAC at 50\/60 Hz with 24 V relay control output and under 5 W standby consumption, matched to the original 62-24268 series application.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eReal-Time Flame Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eThe microprocessor continuously watches the thermostat and flame sensing circuits, stabilizing the flame during operation and helping reduce the risk of gas leakage or flame outage.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eDirect-Fit Marked Terminals\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eTerminals follow the original 62-24268 series layout — photograph the old wiring first, then move each wire to the identically marked terminal with no wire cutting.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eHeat-Resistant Construction\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eBuilt with an enhanced heat-resistant design for dependable, long-term operation inside the furnace control compartment.\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch3 id=\"compatibility\"\u003eCompatibility \u0026amp; Cross-Reference\u003c\/h3\u003e\n\u003ch4\u003eReplaces \/ Interchange Part Numbers:\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003cth style=\"width: 50%;\"\u003eInterchange Part Number\u003c\/th\u003e\n\u003cth\u003eSystem \/ Brand\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1012-925C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBoard number of this replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e62-24268-03\u003c\/td\u003e\n\u003ctd\u003eRheem 62-24268 series (current control)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e62-24268-02\u003c\/td\u003e\n\u003ctd\u003eRheem 62-24268 series (earlier revision)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e62-24268-01\u003c\/td\u003e\n\u003ctd\u003eRheem 62-24268 series (earlier revision)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e62-24192-01\u003c\/td\u003e\n\u003ctd\u003eRheem \/ Ruud earlier control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe Rheem replacement documentation lists the 62-24268-03 as the later revision of this control, replacing the earlier 62-24268-02, 62-24268-01 and 62-24192-01 boards.\u003c\/p\u003e\n\u003ch4\u003eCommon Applications:\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eRheem gas furnaces using a 62-24268 series integrated furnace control (1012-925C)\u003c\/li\u003e\n  \u003cli\u003eRuud gas furnaces using a 62-24268-03, 62-24268-02, 62-24268-01 or 62-24192-01 control board\u003c\/li\u003e\n  \u003cli\u003eWeather King gas furnaces using the 62-24268 series control boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis control runs on standard 24 VAC furnace power with hot surface ignition. It is not a universal board for other furnace brands — before ordering, read the part number printed on your old board and confirm it matches one of the numbers above.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1012-925C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated furnace control (IFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot surface ignition (HSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V control relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor flame sensing with automatic gas-valve shutoff\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62-24268-03 (current); 62-24268-02, 62-24268-01, 62-24192-01 (earlier revisions)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible With\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRheem, Ruud and Weather King gas furnaces using these board numbers\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62-24268 series terminal layout with heat-resistant construction\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × integrated furnace control board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch3\u003eWhy Choose iFJF?\u003c\/h3\u003e\n\u003cp\u003eiFJF supplies furnace control boards factory-direct, so you get the replacement part without the dealership markup. What you can verify before you buy:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eCross-reference you can check yourself:\u003c\/strong\u003e the covered numbers (62-24268-03, 62-24268-02, 62-24268-01 and 62-24192-01) are listed openly above — match your old board number first.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eSpec transparency:\u003c\/strong\u003e 24 VAC 50\/60 Hz input, hot surface ignition and under 5 W standby consumption are stated openly so you can compare them with your original control.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eDIY wiring guidance built in:\u003c\/strong\u003e terminals match the original 62-24268 series layout — photograph the old wiring before removal, then move each wire to the identically marked terminal.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eFactory-direct value:\u003c\/strong\u003e supply straight from the manufacturer keeps the price fair, without the dealership or middleman markup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#fff3e0;border:1px solid #ffb74d;border-radius:4px;padding:12px;margin-bottom:16px;\"\u003e\n  \u003cstrong\u003eInstallation note:\u003c\/strong\u003e replacement should be performed by a qualified HVAC contractor or licensed electrician. Always turn off power and shut off the gas supply before removing the old control. If you are unsure whether this control matches your furnace, message us with the model number printed on your old board before ordering.\n\u003c\/div\u003e\n\u003cp\u003eNeed help finding the right part? Our support team answers fitment questions before you order — \u003cstrong\u003esupport@ifjf.com\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eLooking for related upgrades? Check out our \u003ca href=\"\/products\/1170063-furnace-control-board-replaces-1138-200-icp-furnaces\"\u003eiFJF 1170063 furnace control board for ICP furnaces\u003c\/a\u003e or our \u003ca href=\"\/products\/50a55-843-furnace-control-board-compatible-white-rodgers-lennox\"\u003e50A55-843 furnace control board for White-Rodgers and Lennox furnaces\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"margin-top:12px;\"\u003e📂 \u003cstrong\u003eBrowse More:\u003c\/strong\u003e \u003ca href=\"\/collections\/electronics\"\u003eAll Electronics Products →\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Will this board fit my Rheem furnace?\u003c\/h4\u003e\n\u003cp\u003eA: It replaces original boards numbered 62-24268-01, 62-24268-02, 62-24268-03 or 62-24192-01 in Rheem, Ruud and Weather King gas furnaces. Open the furnace control compartment and read the part number printed on the old board; if it matches one of these four numbers, this board is the direct replacement. Check the \u003ca href=\"#compatibility\"\u003eCross-Reference table\u003c\/a\u003e above before ordering.\u003c\/p\u003e\n\u003ch4\u003eQ: My old board is 62-24268-02. Will the 62-24268-03 replacement work?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. The 62-24268-03 is the later revision of this control and, per the Rheem replacement documentation, replaces the earlier 62-24268-02, 62-24268-01 and 62-24192-01 boards with the same terminal layout.\u003c\/p\u003e\n\u003ch4\u003eQ: Is this an OEM or original Rheem board?\u003c\/h4\u003e\n\u003cp\u003eA: No. This is a third-party compatible replacement designed to the same electrical specification as the original control — 24 VAC at 50\/60 Hz with hot surface ignition — and built to the 62-24268 series layout so wires move over one by one. It is not sold as an OEM part.\u003c\/p\u003e\n\u003ch4\u003eQ: What is included in the package?\u003c\/h4\u003e\n\u003cp\u003eA: One 1012-925C integrated furnace control board. Reuse the mounting hardware already inside your furnace control compartment — no extra screws are needed.\u003c\/p\u003e\n\u003ch4\u003eQ: How hard is the installation for a DIY homeowner?\u003c\/h4\u003e\n\u003cp\u003eA: The terminals match the original 62-24268 series layout, so most buyers move each wire to the identically marked terminal. Turn off the power and shut off the gas first, then photograph the old wiring before removal. If you are not comfortable working with gas appliances, have a qualified HVAC contractor or licensed electrician do the swap.\u003c\/p\u003e\n\u003ch4\u003eQ: How do I know my control board is actually bad?\u003c\/h4\u003e\n\u003cp\u003eA: Common warning signs are no ignition, repeated flame loss, or a burner that starts and stops unexpectedly. The same symptoms can come from the igniter, gas valve or flame sensor, so check those parts first and read the fault code shown by your furnace. Replace the board only after confirming the fault points to the control.\u003c\/p\u003e\n\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × 1012-925C integrated furnace control board\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Problems with Furnace Control Boards — Solved by iFJF\u003c\/h3\u003e\n\u003cp style=\"font-size:0.95em;color:#666;\"\u003eWe analyzed verified customer reviews of OEM and aftermarket control boards in this category. Here is what owners keep complaining about — and how this board addresses it:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr style=\"background:#fafafa;\"\u003e\n\u003cth style=\"width:35%;\"\u003e❌ What Owners Complain About\u003c\/th\u003e\n\u003cth style=\"width:5%;\"\u003e\u003c\/th\u003e\n\u003cth style=\"width:60%;\"\u003e✅ How This Board Addresses It\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003e\"It says compatible but my furnace did not work\"\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#888;\"\u003e— #1 cause of returns in this category\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd style=\"text-align:center;vertical-align:top;padding:10px;\"\u003e→\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003eCheck the board number before you buy\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003eThe covered numbers (62-24268-01, 62-24268-02, 62-24268-03 and 62-24192-01) and the Rheem, Ruud and Weather King fitment are stated openly, so you can verify your old board before ordering. This board is not a universal fit for other furnace brands.\u003c\/span\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003e\"My old board number is different from the one in the listing\"\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#888;\"\u003e— Often an earlier revision of the same control\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd style=\"text-align:center;vertical-align:top;padding:10px;\"\u003e→\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003eOfficial replacement chain made explicit\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003eThe 62-24268-03 is the later revision of this control and replaces the earlier 62-24268-02, 62-24268-01 and 62-24192-01 boards, so a furnace running any of these numbers uses this board directly.\u003c\/span\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003e\"No guidance, worried about wiring it wrong\"\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#888;\"\u003e— Common DIY hesitation\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd style=\"text-align:center;vertical-align:top;padding:10px;\"\u003e→\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003ePhoto-first wiring on marked terminals\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003eTurn off power and gas, photograph the old wiring, then move each wire to the identically marked terminal on the new board — no wire cutting and no guesswork.\u003c\/span\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-top:12px;font-size:0.9em;\"\u003e🔎 \u003cem\u003eWe read the 1-star and 2-star reviews so you don't have to. This board is engineered around the real problems owners face — not just a spec sheet.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f0f7ff;border:1px solid #b8d4f0;border-radius:6px;padding:16px;margin-top:20px\"\u003e\n  \u003cstrong\u003eFactory Direct Supply \u0026amp; Wholesale\u003c\/strong\u003e — iFJF is a direct manufacturer of high-performance replacement parts for heating and filtration systems. Custom specifications and bulk orders are highly welcome. Contact us for exclusive dealer pricing and volume discounts. Backed by \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eIATF 16949:2016\u003c\/strong\u003e quality management system certifications.\u003cbr\u003e\n  \u003cstrong\u003eEmail:\u003c\/strong\u003e support@ifjf.com\n\u003c\/div\u003e\n","brand":"iFJF","offers":[{"title":"Default Title","offer_id":51587220734198,"sku":"FJ-CB-6224","price":179.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/3836\/3894\/files\/image_1_b4daf27b-3300-4ece-b8ce-9c0044ebd4a6.jpg?v=1788589538","url":"https:\/\/ifjf.net\/products\/1012-925c-furnace-control-board-24-vac-hsi-compatible-rheem-ruud","provider":"iFJF Direct","version":"1.0","type":"link"}