{"product_id":"31094-atwood-rv-sail-switch","title":"31094 RV Furnace Sail Switch for Atwood AFM AFLA AFLD DFMD Series","description":"\u003ch2\u003e31094 RV Furnace Sail Switch for Atwood AFM, AFLA, AFLD \u0026amp; DFMD Series — Gray Airflow Safety Switch\u003c\/h2\u003e\n\u003cp\u003eThe iFJF 31094 sail switch is the \u003cstrong\u003eairflow safety switch\u003c\/strong\u003e inside your Atwood \/ Dometic RV furnace that decides whether the burner is allowed to fire. The switch sits in the blower air stream with a hinged paddle: when the blower reaches roughly 75% of its running speed, the airflow lifts the paddle, the contacts close and the control board opens the gas valve. If the blower is weak, a duct is crushed or the battery is low, the paddle never lifts, the circuit stays open and the furnace refuses to ignite — which is exactly what it is supposed to do before unburned propane can collect in the combustion chamber.\u003c\/p\u003e\n\u003cp\u003eThis is a direct replacement for \u003cstrong\u003e31094\u003c\/strong\u003e and the current Dometic service number \u003cstrong\u003e36165 (4471008700)\u003c\/strong\u003e, and it also covers the older \u003cstrong\u003e31094MC, 31093, 33082, 33081 and 33063\u003c\/strong\u003e switches used on the same furnace families. The microswitch is rated \u003cstrong\u003e0.1 A at 125\/250 VAC\u003c\/strong\u003e, uses the original screw terminals and bracket holes, and is built for the AFM, AFLA, AFLD and DFMD furnace series built \u003cem\u003ebefore\u003c\/em\u003e the serial-number cutoffs listed below. One switch per pack.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact 31094 Fit:\u003c\/strong\u003e Same paddle, same bracket footprint and the same screw terminals as the switch you are removing, so it drops onto the existing mounting holes in the blower compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeven Interchange Numbers Covered:\u003c\/strong\u003e 31094, 31094MC, 31093, 33082, 33081, 33063 and 36165 (Dometic 4471008700) — the full range of Atwood numbers an AFM, AFLA, AFLD or DFMD furnace was built with.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.1 A, 125\/250 VAC Microswitch:\u003c\/strong\u003e A genuine airflow-rated microswitch (40T85 temperature class) rather than a generic lever switch pressed into service as a sail switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow-Proving, Not Just a Power Switch:\u003c\/strong\u003e The COM–NO contact pair stays open until the blower actually moves air, so a failed blower or a blocked duct becomes a no-heat condition instead of a gas leak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged Paddle with Repeatable Trip Point:\u003c\/strong\u003e The paddle swings on a hinge pin and lifts at a consistent air velocity, so it does not chatter at low blower speed or stick open after a season of dust.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Screw Terminals, Original Wiring Reused:\u003c\/strong\u003e COM, NO and NC terminals — the furnace uses COM and NO, exactly as the factory switch was wired, with no crimping and no adapter harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-Stable Gray Housing:\u003c\/strong\u003e The molded housing and metal mounting bracket hold their shape and their paddle clearance through repeated heat cycles in the furnace compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne Switch Per Pack:\u003c\/strong\u003e Enough to replace the failed switch in a single furnace — you do not have to buy a two-pack when only one has failed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:34%;\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eBenefit (What It Means for You)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDirect 31094 replacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo drilling, no new connectors and no guessing which revision your furnace was built with — the switch mounts on the same bracket holes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCovers 36165 \/ 4471008700\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIf your parts counter handed you the newer Dometic number — or an older 31093 \/ 33082 — this is the same switch, so an obsolete listing is no longer a dead end.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0.1 A microswitch, 125\/250 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated well above the 12 V DC control circuit it actually switches, so the contacts do not pit from the gas valve's inductive load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormally open at rest\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith the blower off the circuit is open — a no-heat complaint can be traced with a meter at the switch instead of guessing at the control board.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHinged paddle, stable trip point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLifts at the same air velocity every cycle, so the furnace does not short-cycle or drop out mid-heat as the paddle wears in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial-number fitment table\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFM, AFLA, AFLD and DFMD each have their own cutoff, printed below — you can confirm the match from the rating plate before you order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch3 id=\"compatibility\"\u003eCompatibility \u0026amp; Cross-Reference\u003c\/h3\u003e\n\u003cdiv style=\"font-size:0.95em;color:#555;margin-bottom:8px;\"\u003eFits \u003cstrong\u003eAtwood \/ Dometic RV furnaces\u003c\/strong\u003e that use the 31094-style sail switch in the blower air stream. The serial-number cutoffs below come from the manufacturer cross-reference: this switch is listed for furnaces built \u003cstrong\u003ebefore\u003c\/strong\u003e those numbers. Check the model and serial on your furnace rating plate — usually behind the exterior access panel — before ordering.\u003c\/div\u003e\n\u003ch4\u003eReplaces These Part Numbers:\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:30%;\"\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31094\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOriginal Atwood part number — the number this switch is sold under\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31094MC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLater MC Enterprises service version of the same sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31093\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier Atwood service number that crosses to this switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e36165\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Dometic service number (Dometic 4471008700) for this airflow switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e33082\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier Atwood sail switch number that crosses to this part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e33081\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier Atwood sail switch number that crosses to this part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e33063\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier Atwood sail switch number that crosses to this part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4\u003eFurnace Models Covered (serial number cutoffs apply):\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:22%;\"\u003eSeries\u003c\/th\u003e\n\u003cth style=\"width:30%;\"\u003eSerial Number\u003c\/th\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBefore 72489156\u003c\/td\u003e\n\u003ctd\u003eAFMD25111, AFMD25121, AFMD25131, AFMD25141, AFMD25151, AFMD30111, AFMD30121, AFMD30131, AFMD30141, AFMD30151, AFMD35111, AFMD35121, AFMD35131, AFMD35141, AFMD35151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBefore 81689155\u003c\/td\u003e\n\u003ctd\u003eAFLA35211, AFLA35221, AFLA35231, AFLA40211, AFLA40221, AFLA40231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBefore 72991127\u003c\/td\u003e\n\u003ctd\u003eAFLD35111, AFLD35121, AFLD35131, AFLD40111, AFLD40121, AFLD40131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDFMD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBefore 72489156\u003c\/td\u003e\n\u003ctd\u003eDFMD25111, DFMD25121, DFMD25131, DFMD25141, DFMD25151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"background:#f5f7fa;border:1px solid #dfe4ea;border-radius:4px;padding:12px;margin:12px 0;\"\u003e\n\u003cstrong\u003eMatch the serial number as well as the model.\u003c\/strong\u003e The cutoffs above are the manufacturer's cross-reference for this switch, so a furnace built after its series cutoff may use a different service switch. The model and serial are both on the rating plate behind the exterior access panel — if the plate is hard to read, send us a photo and we will confirm before you order.\n\u003c\/div\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:42%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e31094\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaces\u003c\/td\u003e\n\u003ctd\u003e31094MC, 31093, 36165 (4471008700), 33082, 33081, 33063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Type\u003c\/td\u003e\n\u003ctd\u003eSail (airflow-proving) microswitch, SPDT wired on NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e0.1 A at 125\/250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Class\u003c\/td\u003e\n\u003ctd\u003e40T85 (85 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Switched\u003c\/td\u003e\n\u003ctd\u003eFurnace 12 V DC control circuit (gas valve \/ ignition sequence)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator\u003c\/td\u003e\n\u003ctd\u003eHinged sail paddle on metal mounting bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003e3 × screw terminals (COM \/ NO \/ NC); furnace uses COM + NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eGray plastic housing with metal mounting bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Position\u003c\/td\u003e\n\u003ctd\u003eIn the furnace blower air stream, paddle facing airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.54 × 2.36 × 0.59 in (90 × 60 × 15 mm), bracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.63 oz (18 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003e1 × 31094 sail switch (gray)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality\u003c\/td\u003e\n\u003ctd\u003eiFJF Quality Guarantee\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut the gas off at the cylinder and kill the 12 V feed.\u003c\/strong\u003e Close the propane valve at the tank or manifold, then pull the furnace fuse or switch the coach battery disconnect. The blower will still spin on residual power long enough to surprise you.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen the furnace access panel and find the blower housing.\u003c\/strong\u003e On Atwood AFM, AFLA, AFLD and DFMD furnaces the sail switch sits on the blower housing with the paddle reaching into the air stream. Follow the wires rather than guessing at the part.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the wiring before you disconnect it.\u003c\/strong\u003e The switch has COM, NO and NC terminals but the furnace only uses COM and NO. A photo of which lead went where saves you a second trip up the ladder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove the mounting screw and lift the old switch out.\u003c\/strong\u003e Note which way the paddle faced and how far it reached into the air stream — the new switch has to sit at the same depth, with the paddle free to swing, not rubbing the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompare old and new paddle side by side.\u003c\/strong\u003e Same length, same bend, same mounting ear. If the profile differs, stop and contact us — forcing a mismatched paddle is how furnaces end up with a switch that never closes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit the new switch on the same holes and reconnect COM and NO.\u003c\/strong\u003e Leave the NC terminal empty unless your original wiring used it. Restore power and gas, then call for heat: the blower runs first, and after airflow proves out the igniter fires and the burner lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf it still will not light, check airflow before replacing anything else.\u003c\/strong\u003e Look for a crushed or disconnected duct, a return-air restriction, a blower wheel loaded with dust, and battery voltage below roughly 12 V while the blower runs. All three keep the paddle from lifting, and no switch will fix them.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Will this 31094 sail switch fit my Atwood furnace?\u003c\/h4\u003e\n\u003cp\u003eA: It fits the AFM, AFLA, AFLD and DFMD models listed in the compatibility table, provided your furnace serial number is below the cutoff for that series (AFM and DFMD before 72489156, AFLA before 81689155, AFLD before 72991127). Find the model and serial on the rating plate behind the exterior access panel and match them against the table. If the plate shows a number that is not listed, send us a photo of the plate and the old switch and we will confirm before you order.\u003c\/p\u003e\n\n\u003ch4\u003eQ: My furnace lights and then goes out a few seconds later. Is the sail switch the cause?\u003c\/h4\u003e\n\u003cp\u003eA: That is the classic sail switch symptom. The blower starts, the igniter clicks, the burner lights, and then the flame drops out because the switch never confirmed airflow and the control board shut the gas valve again. A dirty flame sensor or a blocked combustion air intake can produce the same sequence, so the first test is a meter across the COM and NO terminals with the blower running — if the contacts never close, the switch or the airflow reaching it is the problem.\u003c\/p\u003e\n\n\u003ch4\u003eQ: How do I test a sail switch to see if it is bad?\u003c\/h4\u003e\n\u003cp\u003eA: Set a multimeter to continuity and put the probes on COM and NO with the wires disconnected. At rest the reading should be open circuit; push the paddle up by hand and it should show continuity. If it stays open when you lift the paddle, or stays closed at rest, the switch has failed. If it tests correctly but the furnace still will not light, the fault is upstream — airflow reaching the switch, the blower, or the control board.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What is the difference between 31094, 31093, 33082 and 36165?\u003c\/h4\u003e\n\u003cp\u003eA: They are all sail switches for the same furnace families and all cross to this replacement. 31094 is the original number for these AFM, AFLA, AFLD and DFMD furnaces; 31094MC is the later MC Enterprises service version; 31093, 33082, 33081 and 33063 are earlier Atwood numbers that cross to the same switch; and 36165 (Dometic 4471008700) is the current service number a dealer will hand you today. Whichever of these numbers is on your old switch, this part replaces it.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Why does the switch have three terminals if the furnace only uses two?\u003c\/h4\u003e\n\u003cp\u003eA: The microswitch itself is a changeover (SPDT) type with COM, NO and NC contacts. Atwood's furnace wiring uses COM and NO, so the NC terminal stays empty. Do not move a lead onto NC to \"make it work\" — that inverts the switch logic and the furnace would try to fire with the blower off.\u003c\/p\u003e\n\n\u003ch4\u003eQ: The blower runs but there is no heat at all. Is that the sail switch?\u003c\/h4\u003e\n\u003cp\u003eA: Sometimes. A sail switch that never closes gives exactly this: blower runs, no ignition, no heat. But the same symptom comes from a failed igniter, a tripped limit switch, a control board that never sends 12 V to the gas valve, or an empty propane tank. The quick discriminator is the igniter: if you hear it clicking and the burner still will not light, check airflow and the sail switch first; if you hear nothing at all, the fault is more likely electrical, upstream of the switch.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can I jumper the sail switch to test whether the furnace will run?\u003c\/h4\u003e\n\u003cp\u003eA: Only as a momentary diagnostic, never as a repair. Jumpering COM and NO tells the control board that airflow is proven, so the burner will fire even with the blower off or the flue blocked — that is a carbon monoxide and fire risk. If a jumpered furnace lights and an un-jumpered furnace does not, the switch is reporting a real airflow problem. Find the restriction, fix it, then fit this switch and remove the jumper.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Does the switch come with the bracket and terminals fitted?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. It arrives as one assembled unit — gray housing, hinged paddle, metal mounting bracket and three screw terminals — one switch per pack. It does not include the furnace wiring harness, the gas valve, the igniter or the control board, because those are separate parts of the furnace.\u003c\/p\u003e\n\n\u003ch3\u003e📊 31094 vs 31093 vs 36165 — Which Sail Switch Does Your Atwood Take?\u003c\/h3\u003e\n\u003cp\u003eFour part numbers, one furnace family and a very common mistake: buying the switch that is cheapest instead of the one that matches the furnace on your coach. Use the table to narrow it down, then confirm against the old part.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:22%;\"\u003ePart\u003c\/th\u003e\n\u003cth style=\"width:30%;\"\u003eListed For\u003c\/th\u003e\n\u003cth style=\"width:22%;\"\u003ePaddle\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e31094\u003c\/strong\u003e (this switch)\u003c\/td\u003e\n\u003ctd\u003eAFM, AFLA, AFLD, DFMD before the serial cutoffs above\u003c\/td\u003e\n\u003ctd\u003eHinged sail, bracket mounted\u003c\/td\u003e\n\u003ctd\u003eOriginal number; crosses to 31094MC, 31093, 33082, 33081, 33063 and 36165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31093\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFS and AFM furnaces with earlier serials\u003c\/td\u003e\n\u003ctd\u003eSame sail-switch design\u003c\/td\u003e\n\u003ctd\u003eEarlier Atwood number — this switch replaces it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e36165\u003c\/strong\u003e (4471008700)\u003c\/td\u003e\n\u003ctd\u003eCurrent Dometic service number for the same furnaces\u003c\/td\u003e\n\u003ctd\u003eSame family as 31094\u003c\/td\u003e\n\u003ctd\u003eWhat a dealer will sell you today; this switch covers it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e36680\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAtwood Hydro Flame furnaces (7900 \/ 8500 \/ 8900 series)\u003c\/td\u003e\n\u003ctd\u003eDifferent housing and bracket\u003c\/td\u003e\n\u003ctd\u003eA different furnace family — do not substitute it for a 31094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:0.92em;color:#555;\"\u003eA sail switch that reads open at rest is normal. A sail switch that reads open with the blower running and the paddle lifted by hand is not — that is the one to replace with this 31094.\u003c\/p\u003e\n\n\u003ch3\u003e📦 Related Products \u0026amp; Guides\u003c\/h3\u003e\n\u003cp\u003eParts our customers keep on hand for Atwood RV furnace and water heater repairs.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:42%;\"\u003eProduct\u003c\/th\u003e\n\u003cth style=\"width:42%;\"\u003eFits\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/36680-atwood-rv-sail-switch\"\u003e36680 Sail Switch for Atwood Hydro Flame\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eHydro Flame 7900 \/ 8500 \/ 8900 furnaces — the other sail switch Atwood used\u003c\/td\u003e\n\u003ctd\u003e$29.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/ifjf-93866-water-heater-thermal-cutoff-switch-kit-for-rv-atwood-camper-gas-water-heater\"\u003e93866 Water Heater Thermal Cutoff Switch Kit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAtwood RV gas water heaters — the thermal safety switch in the same appliance family\u003c\/td\u003e\n\u003ctd\u003e$23.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/ifjf-93868-for-atwood-rv-water-heater-parts-rv-spark-sensor-electrode-2-prong\"\u003e93868 RV Spark \u0026amp; Sensor Electrode\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAtwood RV water heaters — igniter and flame sense in one part\u003c\/td\u003e\n\u003ctd\u003e$39.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eBrowse more \u003ca href=\"\/collections\/rv-parts\"\u003eRV parts and generator accessories\u003c\/a\u003e we stock, or read the cross-reference table below before you order.\u003c\/p\u003e\n\n\u003ch3\u003e🔄 31094 Cross Reference \u0026amp; Fitment Notes\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:32%;\"\u003eNumber \/ Term\u003c\/th\u003e\n\u003cth\u003eWhat It Is\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31094\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAtwood sail switch, original part number — the switch this unit replaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31094MC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC Enterprises service version of the same sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e36165 \/ 4471008700\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Dometic service number for this airflow switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e33082 \/ 33081 \/ 33063\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier Atwood sail switch numbers that cross to 31094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31093\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier Atwood service number for AFS and AFM furnaces — crosses to this switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSail switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlso listed as an airflow switch or air-proving switch — same device, sold by function on some pages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature safety device — \u003cstrong\u003enot\u003c\/strong\u003e interchangeable with this sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgniter \/ spark electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate ignition part — replacing it will not fix an airflow fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:0.9em;color:#555;\"\u003eAtwood and Dometic are trademarks of their respective owners and are referenced here only to identify the furnaces and part numbers this switch fits. This is an iFJF aftermarket sail switch, not a genuine Atwood or Dometic part. It does not include the furnace, the blower, the gas valve, the igniter or the wiring harness.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f0f7ff;border:1px solid #b8d4f0;border-radius:6px;padding:16px;margin-top:20px;\"\u003e\n\u003cstrong\u003eNot sure your furnace takes a 31094?\u003c\/strong\u003e Send us a photo of the furnace rating plate and the switch you are removing, with the paddle and wiring visible. Our team will confirm the match before you order.\u003cbr\u003e\n\u003cstrong\u003eEmail:\u003c\/strong\u003e support@ifjf.com\u003cbr\u003e\n\u003cspan style=\"font-size:0.9em;\"\u003eBacked by \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eIATF 16949:2016\u003c\/strong\u003e quality management system certifications.\u003c\/span\u003e\n\u003c\/div\u003e\n","brand":"iFJF","offers":[{"title":"Default Title","offer_id":52475728396534,"sku":"FJ-X-SS08-GY","price":35.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/3836\/3894\/files\/98140d2d83addc6a93c91687e528cec2.jpg?v=1795414780","url":"https:\/\/ifjf.net\/products\/31094-atwood-rv-sail-switch","provider":"iFJF Direct","version":"1.0","type":"link"}