{"product_id":"33082-atwood-rv-sail-switch","title":"33082 RV Furnace Sail Switch with Bracket for Atwood AFM AFLA AFLD","description":"\u003ch2\u003e33082 RV Furnace Sail Switch with Upgrade Bracket for Atwood \/ Dometic AFM, AFLA, AFLD \u0026amp; DFMD — Replaces 31094 on Later Serials\u003c\/h2\u003e\n\u003cp\u003eThe iFJF 33082 sail switch is the \u003cstrong\u003eairflow safety switch\u003c\/strong\u003e fitted to later-build Atwood \/ Dometic RV furnaces. It sits in the blower air stream with a long flat blade: when the blower comes up to speed the blade is lifted, the contacts close and the control board opens the gas valve. If airflow is weak — a dusty blower wheel, a crushed duct or a low battery — the blade never lifts and the furnace refuses to ignite, which is exactly how the switch is meant to protect you from unburned propane collecting in the combustion chamber.\u003c\/p\u003e\n\u003cp\u003eThis is the later-serial replacement for furnaces built \u003cstrong\u003eafter\u003c\/strong\u003e the manufacturer's serial-number cutoffs, crossing to \u003cstrong\u003e33082\u003c\/strong\u003e (and the current 36165 service kit). On these furnaces the factory changed from the older hinged-paddle 31094 switch to a \u003cstrong\u003eflat-blade 33082\u003c\/strong\u003e pattern — the two are not interchangeable. The kit includes the switch, a \u003cstrong\u003ereinforced replacement bracket\u003c\/strong\u003e and two mounting screws: the original plastic bracket is a known failure point that cracks and leaves the switch insensitive, so fitting the new bracket along with the switch is the repair that actually lasts. One complete kit per pack.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrect Switch for Later Serials:\u003c\/strong\u003e Fits AFM (AFMD), AFLD, AFLA and DFMD furnaces built \u003cem\u003eafter\u003c\/em\u003e serial 72489156, 72991127 and 81689155 respectively — the furnaces that left the factory with the flat-blade 33082 design, not the earlier 31094.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReinforced Bracket Included:\u003c\/strong\u003e The original equipment bracket is prone to cracking, which makes the switch insensitive or damages it. This kit ships with an upgraded bracket plus two screws so you replace the weak part at the same time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat Blade, Not a Hinged Paddle:\u003c\/strong\u003e A long, straight metal blade with a wide sensing area replaces the small hinged paddle used on the earlier switch. Compare your old blade to the photo before ordering — flat blade means 33082, hinged paddle means 31094.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrosses to 33082 \/ 36165:\u003c\/strong\u003e The part number an RV parts counter will quote for these later furnaces. Also covers the AFS and AFMD16\/AFMD20 later-serial switches (33081) noted in the cross-reference below.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.1 A Microswitch, 125\/250 VAC \u0026amp; 30 VDC:\u003c\/strong\u003e An airflow-rated microswitch (40T85, 85 °C) with three terminals, rated well above the 12 V DC furnace control circuit it actually switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree Screw Terminals, Original Wiring Reused:\u003c\/strong\u003e COM, NO and NC terminals — the furnace uses COM and NO exactly as the factory switch was wired, with no crimping and no adapter harness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple Drop-In Install:\u003c\/strong\u003e The upgraded bracket locates on the blower housing and the two included screws secure it. No drilling, no modification to the furnace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Kit, One Pack:\u003c\/strong\u003e 1 × flat-blade sail switch, 1 × upgraded bracket, 2 × screws and an installation sheet — everything needed for the repair in one bag.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:34%;\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eBenefit (What It Means for You)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlat-blade 33082 design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMatches the switch fitted to later-build furnaces. Order the earlier 31094 by mistake and the paddle profile will not match — this one does.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpgraded replacement bracket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe factory bracket cracks with heat and age; a cracked bracket gives an intermittent or dead switch. Fitting the new one with the switch fixes the root cause, not just the symptom.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 screws included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo trip to the hardware store mid-repair — the fasteners to secure the new bracket are in the bag.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0.1 A, 125\/250 VAC \u0026amp; 30 VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContact rating far above the furnace's low-voltage control circuit, so the gas-valve load does not pit the contacts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormally open at rest\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith the blower off the circuit is open. A no-heat fault can be traced with a meter at the switch instead of guessing at the control board.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial-number fitment table\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFM, AFLA, AFLD and DFMD each have their own cutoff, printed below — confirm the match from the rating plate before you order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch3 id=\"compatibility\"\u003eCompatibility \u0026amp; Cross-Reference\u003c\/h3\u003e\n\u003cdiv style=\"font-size:0.95em;color:#555;margin-bottom:8px;\"\u003eFits \u003cstrong\u003eAtwood \/ Dometic RV furnaces\u003c\/strong\u003e that use the flat-blade 33082 sail switch in the blower air stream. This switch is listed for furnaces built \u003cstrong\u003eafter\u003c\/strong\u003e the serial-number cutoffs below — the point at which the factory moved from the earlier 31094 hinged-paddle switch. Find the model and serial on the furnace rating plate, usually behind the exterior access panel, before ordering.\u003c\/div\u003e\n\u003ch4\u003eFurnace Models Covered (serial number cutoffs apply):\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:20%;\"\u003eSeries\u003c\/th\u003e\n\u003cth style=\"width:28%;\"\u003eSerial Number\u003c\/th\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFM (AFMD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 72489156\u003c\/td\u003e\n\u003ctd\u003eAFMD25111, AFMD25121, AFMD25131, AFMD25141, AFMD25151, AFMD30111, AFMD30121, AFMD30131, AFMD30141, AFMD30151, AFMD35111, AFMD35121, AFMD35131, AFMD35141, AFMD35151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 72991127\u003c\/td\u003e\n\u003ctd\u003eAFLD35111, AFLD35121, AFLD35131, AFLD40111, AFLD40121, AFLD40131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAFLA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 81689155\u003c\/td\u003e\n\u003ctd\u003eAFLA35211, AFLA35221, AFLA35231, AFLA40211, AFLA40221, AFLA40231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDFMD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAfter 72489156\u003c\/td\u003e\n\u003ctd\u003eDFMD25111, DFMD25121, DFMD25131, DFMD25141, DFMD25151, DFMD30111, DFMD30121, DFMD30131, DFMD30141, DFMD30151, DFMD35111, DFMD35121, DFMD35131, DFMD35141, DFMD35151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"background:#fff8e1;border:1px solid #ffe082;border-radius:4px;padding:12px;margin:12px 0;\"\u003e\n\u003cstrong\u003eBefore you order, match the blade.\u003c\/strong\u003e The serial cutoffs are a guide, not a guarantee — Atwood used more than one switch across these ranges. Take the old switch out and lay it beside this one: a \u003cstrong\u003elong flat blade\u003c\/strong\u003e means 33082 (this switch); a \u003cstrong\u003esmall hinged paddle\u003c\/strong\u003e means the earlier 31094. If your original does not match the photo, send us a picture and we will point you at the right part before you install anything.\n\u003c\/div\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:42%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e33082\u003c\/strong\u003e (later-serial sail switch, flat-blade type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaces\u003c\/td\u003e\n\u003ctd\u003e33082; crosses to the 36165 (4471008700) service kit used on these later furnaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Type\u003c\/td\u003e\n\u003ctd\u003eSail (airflow-proving) microswitch, SPDT wired on NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e0.1 A at 125\/250 VAC; 0.1 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Class\u003c\/td\u003e\n\u003ctd\u003e40T85 (85 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Switched\u003c\/td\u003e\n\u003ctd\u003eFurnace 12 V DC control circuit (gas valve \/ ignition sequence)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator\u003c\/td\u003e\n\u003ctd\u003eLong flat metal blade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003e3 × screw terminals (COM \/ NO \/ NC); furnace uses COM + NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eBlack plastic microswitch body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eUpgraded replacement bracket, secured with the 2 included screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Size\u003c\/td\u003e\n\u003ctd\u003e3.5 × 3.5 × 0.8 in (switch and bracket assembled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003e1 × flat-blade sail switch, 1 × upgraded bracket, 2 × screws, 1 × installation sheet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality\u003c\/td\u003e\n\u003ctd\u003eiFJF Quality Guarantee\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut the gas off at the cylinder and kill the 12 V feed.\u003c\/strong\u003e Close the propane valve at the tank or manifold, then pull the furnace fuse or switch the coach battery disconnect. The blower can still spin on residual power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen the furnace access panel and find the blower housing.\u003c\/strong\u003e On Atwood AFM, AFLD, AFLA and DFMD furnaces the sail switch sits on the blower housing with the blade reaching into the air stream. Follow the wires rather than guessing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the wiring before you disconnect it.\u003c\/strong\u003e The switch has COM, NO and NC terminals but the furnace uses COM and NO. A photo of which lead went where saves a second trip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove the old switch and its bracket.\u003c\/strong\u003e Note which way the blade faced and how far it reached into the air stream — the new switch has to sit at the same depth with the blade free to move, not rubbing the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompare old and new blade side by side.\u003c\/strong\u003e A long flat blade matches this 33082 kit. If your original has a small hinged paddle, stop — you need the earlier 31094 instead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit the upgraded bracket with the two included screws, then reconnect COM and NO.\u003c\/strong\u003e Leave NC empty unless your original wiring used it. Restore power and gas, then call for heat: the blower runs first, and once airflow proves out the igniter fires and the burner lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf it still will not light, check airflow before replacing anything else.\u003c\/strong\u003e Look for a crushed or disconnected duct, a return-air restriction, a blower wheel loaded with dust, and battery voltage below roughly 12 V while the blower runs. No switch will fix those.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Will this 33082 sail switch fit my Atwood furnace?\u003c\/h4\u003e\n\u003cp\u003eA: It fits the AFM (AFMD), AFLD, AFLA and DFMD models in the compatibility table, provided your furnace serial number is above the cutoff for that series — AFM and DFMD after 72489156, AFLD after 72991127, AFLA after 81689155. Check the model and serial on the rating plate behind the exterior access panel. If your serial is below the cutoff, you need the earlier 31094 switch instead. If the plate shows a number that is not listed, send us a photo of the plate and the old switch and we will confirm before you order.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What is the difference between 33082 and 31094?\u003c\/h4\u003e\n\u003cp\u003eA: They are the two generations of sail switch used on the same furnace families, split by serial number. The earlier 31094 uses a small hinged paddle and fits furnaces built before the cutoffs. The later 33082 — this switch — uses a long flat blade and fits furnaces built after them. The two are not interchangeable. Take your old switch out and compare the blade: flat blade means 33082, hinged paddle means 31094.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Why does the kit include a bracket?\u003c\/h4\u003e\n\u003cp\u003eA: The original plastic bracket on these furnaces is a well-known weak point — it cracks with heat and age, leaving the switch loose, insensitive or damaged. Fitting a new switch on a cracked bracket often fixes nothing for long. This kit includes a reinforced replacement bracket and two screws so the underlying problem is sorted at the same time. We recommend using the upgraded bracket whenever you replace this switch.\u003c\/p\u003e\n\n\u003ch4\u003eQ: My furnace lights and then goes out a few seconds later. Is the sail switch the cause?\u003c\/h4\u003e\n\u003cp\u003eA: That is a classic sail switch symptom. The blower starts, the igniter clicks, the burner lights, and then the flame drops out because the switch never confirmed airflow and the control board shut the gas valve again. A dirty flame sensor or blocked combustion air intake can do the same, so the first test is a meter across COM and NO with the blower running — if the contacts never close, the switch or the airflow reaching it is the problem.\u003c\/p\u003e\n\n\u003ch4\u003eQ: How do I test a sail switch to see if it is bad?\u003c\/h4\u003e\n\u003cp\u003eA: Set a multimeter to continuity and put the probes on COM and NO with the wires disconnected. At rest the reading should be open circuit; lift the blade by hand and it should show continuity. If it stays open when you lift the blade, or stays closed at rest, the switch has failed. If it tests correctly but the furnace still will not light, the fault is upstream — airflow reaching the switch, the blower, or the control board.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Why does the switch have three terminals if the furnace only uses two?\u003c\/h4\u003e\n\u003cp\u003eA: The microswitch itself is a changeover (SPDT) type with COM, NO and NC contacts. Atwood \/ Dometic furnace wiring uses COM and NO, so NC stays empty. Do not move a lead onto NC to \"make it work\" — that inverts the switch logic and the furnace would try to fire with the blower off.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can I jumper the sail switch to test whether the furnace will run?\u003c\/h4\u003e\n\u003cp\u003eA: Only as a momentary diagnostic, never as a repair. Jumpering COM and NO tells the control board that airflow is proven, so the burner fires even with the blower off or the flue blocked — a carbon monoxide and fire risk. If a jumpered furnace lights and an un-jumpered furnace does not, the switch is reporting a real airflow problem. Find the restriction, fix it, then fit this switch and remove the jumper.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What comes in the pack?\u003c\/h4\u003e\n\u003cp\u003eA: One complete kit: a flat-blade 33082 sail switch, one upgraded replacement bracket, two mounting screws and an installation sheet. It does not include the furnace wiring harness, gas valve, igniter or control board, because those are separate parts.\u003c\/p\u003e\n\n\u003ch3\u003e📊 33082 vs 31094 vs 33081 — Which Sail Switch Does Your Furnace Take?\u003c\/h3\u003e\n\u003cp\u003eThree part numbers, one serial-number split and one very common mistake: buying the switch that fits the earlier furnace. Narrow it down with the table, then confirm against the old part you remove.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:22%;\"\u003ePart\u003c\/th\u003e\n\u003cth style=\"width:30%;\"\u003eListed For\u003c\/th\u003e\n\u003cth style=\"width:22%;\"\u003eActuator\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e33082\u003c\/strong\u003e (this kit)\u003c\/td\u003e\n\u003ctd\u003eAFM\/AFMD, AFLD, AFLA, DFMD after the serial cutoffs above\u003c\/td\u003e\n\u003ctd\u003eLong flat blade\u003c\/td\u003e\n\u003ctd\u003eLater-serial switch; kit includes the upgraded bracket and 2 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"\/products\/31094-atwood-rv-sail-switch\"\u003e31094\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame furnace series before the serial cutoffs\u003c\/td\u003e\n\u003ctd\u003eSmall hinged paddle\u003c\/td\u003e\n\u003ctd\u003eEarlier generation — not interchangeable with the flat-blade 33082\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e33081\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFS and AFMD16 \/ AFMD20 furnaces after serial 72498929\u003c\/td\u003e\n\u003ctd\u003eFlat blade\u003c\/td\u003e\n\u003ctd\u003eLater switch for the AFS and 16\/20k BTU families; compare before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31093\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAFS and AFMD16 \/ AFMD20 furnaces before serial 72498929\u003c\/td\u003e\n\u003ctd\u003eHinged paddle\u003c\/td\u003e\n\u003ctd\u003eEarlier switch for those families — the counterpart to 33081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:0.92em;color:#555;\"\u003eA sail switch that reads open at rest is normal. A sail switch that reads open with the blower running and the blade lifted by hand is not — that is the one to replace with this 33082 kit.\u003c\/p\u003e\n\n\u003ch3\u003e📦 Related Products \u0026amp; Guides\u003c\/h3\u003e\n\u003cp\u003eParts our customers keep on hand for Atwood RV furnace and water heater repairs.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:42%;\"\u003eProduct\u003c\/th\u003e\n\u003cth style=\"width:42%;\"\u003eFits\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/36680-atwood-rv-sail-switch\"\u003e36680 Sail Switch for Atwood Hydro Flame\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAtwood Hydro Flame 7900 \/ 8500 \/ 8900 furnaces — a different sail switch family\u003c\/td\u003e\n\u003ctd\u003e$29.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/ifjf-93866-water-heater-thermal-cutoff-switch-kit-for-rv-atwood-camper-gas-water-heater\"\u003e93866 Water Heater Thermal Cutoff Switch Kit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAtwood RV gas water heaters — the thermal safety switch in the same appliance family\u003c\/td\u003e\n\u003ctd\u003e$23.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/ifjf-93868-for-atwood-rv-water-heater-parts-rv-spark-sensor-electrode-2-prong\"\u003e93868 RV Spark \u0026amp; Sensor Electrode\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eAtwood RV water heaters — igniter and flame sense in one part\u003c\/td\u003e\n\u003ctd\u003e$39.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eBrowse more \u003ca href=\"\/collections\/rv-parts\"\u003eRV parts and generator accessories\u003c\/a\u003e we stock, or read the cross-reference table below before you order.\u003c\/p\u003e\n\n\u003ch3\u003e🔄 33082 Cross Reference \u0026amp; Fitment Notes\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:32%;\"\u003eNumber \/ Term\u003c\/th\u003e\n\u003cth\u003eWhat It Is\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e33082\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLater-serial Atwood \/ Dometic sail switch — the switch this kit replaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e36165 \/ 4471008700\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Dometic service number and kit ID for this later sail switch family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31094\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier hinged-paddle switch for the same furnaces before the serial cutoffs — not interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e33081 \/ 31093\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLater \/ earlier switch pair for the AFS and AFMD16 \/ AFMD20 furnace families\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSail switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlso listed as an airflow switch or air-proving switch — same device, sold by function on some pages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature safety device — \u003cstrong\u003enot\u003c\/strong\u003e interchangeable with this sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgniter \/ spark electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate ignition part — replacing it will not fix an airflow fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:0.9em;color:#555;\"\u003eAtwood and Dometic are trademarks of their respective owners and are referenced here only to identify the furnaces and part numbers this switch fits. This is an iFJF aftermarket sail switch kit, not a genuine Atwood or Dometic part. It does not include the furnace, the blower, the gas valve, the igniter or the wiring harness.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f0f7ff;border:1px solid #b8d4f0;border-radius:6px;padding:16px;margin-top:20px;\"\u003e\n\u003cstrong\u003eNot sure your furnace takes a 33082 or a 31094?\u003c\/strong\u003e Send us a photo of the furnace rating plate and the switch you are removing, with the blade and wiring visible. Our team will confirm the match before you order.\u003cbr\u003e\n\u003cstrong\u003eEmail:\u003c\/strong\u003e support@ifjf.com\u003cbr\u003e\n\u003cspan style=\"font-size:0.9em;\"\u003eBacked by \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eIATF 16949:2016\u003c\/strong\u003e quality management system certifications.\u003c\/span\u003e\n\u003c\/div\u003e\n","brand":"iFJF","offers":[{"title":"Default Title","offer_id":52475837284598,"sku":"FJ-X-SS07-CK","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/3836\/3894\/files\/f04a55c875093f9139428be2479a0c5c.jpg?v=1795414996","url":"https:\/\/ifjf.net\/products\/33082-atwood-rv-sail-switch","provider":"iFJF Direct","version":"1.0","type":"link"}