{"product_id":"36680-atwood-rv-sail-switch","title":"36680 Sail Switch for Atwood Hydro Flame RV Furnace — Replaces 31377","description":"\u003ch2\u003e36680 Sail Switch for Atwood Hydro Flame RV Furnace — Gray, 250 VAC Airflow Safety Switch\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe iFJF 36680 sail switch is the \u003cstrong\u003eairflow safety switch\u003c\/strong\u003e that decides whether your Atwood \/ Hydro Flame RV furnace is allowed to fire. It sits in the blower air stream with a hinged plastic sail: when the blower pushes enough air, the sail lifts, the contacts close and the gas valve opens. When airflow drops — weak blower, blocked duct, low battery — the sail stays down, the contacts stay open and the furnace will not ignite. That is not a fault; it is the switch doing its job before unburned propane can build up in the combustion chamber.\u003c\/p\u003e\n\u003cp\u003eIt is a direct replacement for \u003cstrong\u003e36680\u003c\/strong\u003e (the old Atwood SKU) and \u003cstrong\u003e31377\u003c\/strong\u003e (the current Dometic part number), and it also covers \u003cstrong\u003e35050, 35052, 35054, 35137, 36133 and 37716\u003c\/strong\u003e. The switch is rated \u003cstrong\u003e250 VAC\u003c\/strong\u003e, uses screw terminals on the original two leads, and mounts on the same bracket holes — no wiring change, no adapter. This listing is the \u003cstrong\u003egray\u003c\/strong\u003e version, one switch per pack.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact 36680 \/ 31377 Replacement:\u003c\/strong\u003e Same sail shape, same bracket footprint and the same two screw terminals as the switch you are removing — it drops onto the existing mounting holes in the blower compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight Interchange Numbers Covered:\u003c\/strong\u003e 36680, 31377, 35050, 35052, 35054, 35137, 36133 and 37716 — the full range of Atwood \/ Hydro Flame part numbers that cross to this switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e250 VAC Contact Rating:\u003c\/strong\u003e Rated far above the 12 V DC control circuit it actually switches, so the contacts do not pit from the furnace's inductive load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormally Open, Closes on Airflow:\u003c\/strong\u003e A true airflow-proving switch — the circuit stays open until the blower actually moves air, which is what makes it a safety device and not just a power switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged Sail Paddle:\u003c\/strong\u003e The paddle hangs from a hinge pin and lifts at a repeatable air velocity, so it does not chatter at low blower speed or stick open after a season of dust.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew Terminals, Original Lead Positions:\u003c\/strong\u003e Two spade-style screw terminals take the existing leads. Polarity does not matter for the switch function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGray Glass-Filled Plastic Housing:\u003c\/strong\u003e The molded housing and metal mounting bracket hold their shape in the heat of a furnace compartment, where a soft plastic switch would warp and jam.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne Switch Per Pack:\u003c\/strong\u003e Enough to replace the failed switch in a single furnace — no need to buy a two-pack when only one has failed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:34%;\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eBenefit (What It Means for You)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow-proving sail paddle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe furnace cannot open the gas valve until the blower actually moves air — the exact condition this switch was designed to enforce.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrosses to 8 Atwood \/ Dometic numbers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne part covers the older 35050 \/ 35137 \/ 37716 furnaces and the current 31377 service number, so you order once instead of guessing which revision your coach was built with.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e250 VAC rated contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitching a 12 V DC gas-valve circuit through a 250 V AC rated contact set means the points stay clean far longer than a switch rated only for the load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormally open at rest\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith the blower off the circuit is open. A no-heat complaint can be traced with a meter at the switch instead of guessing at the control board.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSame bracket and screw terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo drilling, no crimping, no new connectors — the swap is a screwdriver job inside the blower compartment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat-stable gray housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHolds its shape and its sail clearance through repeated heat cycles, so the switch does not start sticking in its second or third season.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch3 id=\"compatibility\"\u003eCompatibility \u0026amp; Cross-Reference\u003c\/h3\u003e\n\u003cdiv style=\"font-size:0.95em;color:#555;margin-bottom:8px;\"\u003eFits \u003cstrong\u003eAtwood \/ Hydro Flame RV furnaces\u003c\/strong\u003e that use the 36680-style sail switch in the blower air stream. Match the model number on your furnace's rating plate against the tables below before ordering.\u003c\/div\u003e\n\u003ch4\u003eReplaces These Part Numbers:\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:30%;\"\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e36680\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOriginal Atwood part number — the number this switch is sold under\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31377\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Dometic \/ Atwood service number for the same switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e35050\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarly Hydro Flame furnace sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e35052\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarly Hydro Flame furnace sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e35054\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarly Hydro Flame furnace sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e35137\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarly Hydro Flame furnace sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e36133\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntermediate service number that crosses to 36680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e37716\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntermediate service number that crosses to 36680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4\u003eFurnace Models Covered:\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:26%;\"\u003eSeries\u003c\/th\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1522 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1522 2-Stage, 1522 LD 2-Stage, XT-1522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2334 \/ 2540\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2334 2-Stage, 2540 2-Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7900 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7912-II, 7916-II, 7920-II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8500 Series II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8516-II, 8520-II, 8525-II, 8531-II, 8535-II; 85-II 16-20, 85-II 31-35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8500 Series III\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8516-III, 8520-III, 8525-III, 8531-III, 8535-III; 85-III 31-35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8500 Series IV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8516-IV, 8520-IV, 8525-IV, 8531-IV, 8535-IV; 85-IV 16, 85-IV 20, 85-IV 25, 85-IV 31, 85-IV 35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8900 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8935-DC-I, 8935-AC-I, 8940-DC-I, 8940-AC-I, 8935-DC-II, 8935-AC-II, 8940-DC-II, 8940-AC-II, 8935-DC-III, 8935-AC-III, 8940-DC-III, 8940-AC-III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"background:#fff8e1;border:1px solid #ffe082;border-radius:4px;padding:12px;margin:12px 0;\"\u003e\n\u003cstrong\u003eDo not bypass this switch to \"make the furnace run.\"\u003c\/strong\u003e Jumpering the two leads will fire the burner whether or not the blower is moving air, which is exactly the condition the switch exists to prevent. If a jumpered furnace runs and a furnace with this switch does not, the problem is airflow — a blocked duct, a collapsed flexible hose, a dirty blower wheel or a battery too low to spin the blower at full speed — not a \"bad switch.\" Fix the airflow first, then fit the new switch.\n\u003c\/div\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:42%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e36680\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaces\u003c\/td\u003e\n\u003ctd\u003e31377, 35050, 35052, 35054, 35137, 36133, 37716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Type\u003c\/td\u003e\n\u003ctd\u003eSail (airflow-proving) switch, SPST normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Switched\u003c\/td\u003e\n\u003ctd\u003eFurnace 12 V DC control circuit (gas valve \/ ignition sequence)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator\u003c\/td\u003e\n\u003ctd\u003eHinged sail paddle on mounting bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003e2 × screw terminals, existing leads reused\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eGray plastic housing with metal mounting bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Position\u003c\/td\u003e\n\u003ctd\u003eIn the furnace blower air stream, paddle facing airflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 2.5 × 0.5 × 0.31 in (64 × 13 × 8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.7 oz (20 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003e1 × 36680 sail switch (gray)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality\u003c\/td\u003e\n\u003ctd\u003eiFJF Quality Guarantee\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eShut the gas off at the cylinder and kill the 12 V feed.\u003c\/strong\u003e Close the propane valve at the tank or at the manifold, then pull the furnace fuse or switch the coach battery disconnect. The blower will still spin on residual power long enough to surprise you.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen the furnace access panel.\u003c\/strong\u003e On most Atwood \/ Hydro Flame installations the sail switch sits on the blower housing, downstream of the blower wheel, with two leads running to it. Follow the wires rather than guessing at the part.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotograph the wiring before you disconnect it.\u003c\/strong\u003e The switch itself is not polarity sensitive, but the two leads need to go back on the same two terminals, and a photo saves you a second trip up the ladder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove the mounting screw and lift the old switch out.\u003c\/strong\u003e Note which way the sail paddle faced — the new switch has to face the same way, with the paddle free to swing into the airflow, not against the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit the new switch on the same holes.\u003c\/strong\u003e Set the paddle so it hangs into the air stream and swings freely through its full travel. If the paddle touches the housing or the blower wheel, the switch will never close.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReconnect the two leads and restore power and gas.\u003c\/strong\u003e Start the thermostat call for heat: the blower runs first, and after the airflow proves out — typically 15 to 30 seconds — the igniter fires and the burner lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf it still will not light, check airflow before replacing anything else.\u003c\/strong\u003e Look for a crushed or disconnected duct, a return-air restriction, a blower wheel loaded with dust, and battery voltage below roughly 12 V while the blower runs. All three keep the sail from lifting, and no switch will fix them.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Will this 36680 sail switch fit my Atwood Hydro Flame furnace?\u003c\/h4\u003e\n\u003cp\u003eA: It fits the furnace models listed in the compatibility table above, and it replaces part numbers 36680, 31377, 35050, 35052, 35054, 35137, 36133 and 37716. Find the model number on the furnace rating plate — usually behind the exterior access panel — and match it against the series table. If the plate shows a number that is not listed, send us a photo of the plate and the old switch and we will confirm before you order.\u003c\/p\u003e\n\n\u003ch4\u003eQ: My furnace ignites and then goes out a few seconds later. Is the sail switch the cause?\u003c\/h4\u003e\n\u003cp\u003eA: That is the classic sail switch symptom. The sequence is: blower starts, the igniter clicks, the burner lights, and then the flame drops out because the switch never confirmed airflow and the control board shut the gas valve again. It can also be caused by a dirty flame sensor or a blocked combustion air intake, so the first test is a meter across the switch leads with the blower running — if the contacts never close, the switch or the airflow to it is the problem.\u003c\/p\u003e\n\n\u003ch4\u003eQ: How do I test a sail switch to see if it is bad?\u003c\/h4\u003e\n\u003cp\u003eA: Set a multimeter to continuity or resistance and put the probes on the two terminals with the wires disconnected. With the paddle at rest the reading should be open circuit. Push the paddle up by hand and the meter should show continuity. If it stays open when you lift the paddle, or stays closed at rest, the switch has failed. If it tests correctly but the furnace still will not light, the fault is upstream — airflow reaching the switch, the blower, or the control board.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Is 36680 the same part as 31377?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. 36680 is the older Atwood number and 31377 is the current Dometic \/ Atwood service number for the same sail switch. Both numbers, plus 35050, 35052, 35054, 35137, 36133 and 37716, are listed on this switch because they all cross to the same replacement.\u003c\/p\u003e\n\n\u003ch4\u003eQ: What voltage is this switch rated for?\u003c\/h4\u003e\n\u003cp\u003eA: The contacts are rated 250 VAC. In the furnace it switches the 12 V DC control circuit that feeds the gas valve and ignition sequence, so the contact rating is well above the load it actually carries. Do not use it as a line-voltage switch for 120 V or 240 V appliances — it is a furnace airflow switch, not a general-purpose power switch.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Can I jumper the sail switch to test whether the furnace will run?\u003c\/h4\u003e\n\u003cp\u003eA: Only as a momentary diagnostic, never as a repair. Jumpering the two leads tells the control board that airflow is proven, so the burner will fire even with the blower off or the flue blocked — that is a carbon monoxide and fire risk. If a jumpered furnace lights and an un-jumpered furnace does not, the switch is reporting a real airflow problem. Find the airflow restriction and fix it, then fit this switch and remove the jumper.\u003c\/p\u003e\n\n\u003ch4\u003eQ: The blower runs but there is no heat at all. Is that the sail switch?\u003c\/h4\u003e\n\u003cp\u003eA: Sometimes. A sail switch that never closes produces exactly this: blower runs, no ignition, no heat. But the same symptom comes from a failed igniter, a tripped limit switch, a control board that never sends 12 V to the gas valve, or an empty propane tank. The quick discriminator is the igniter: if you hear it clicking and the burner still will not light, airflow and the sail switch are the first things to check; if you hear nothing at all, the fault is more likely electrical, upstream of the switch.\u003c\/p\u003e\n\n\u003ch4\u003eQ: Does the switch come with the bracket and terminals fitted?\u003c\/h4\u003e\n\u003cp\u003eA: Yes. The switch arrives as one assembled unit — gray housing, hinged sail paddle, metal mounting bracket and two screw terminals — one switch per pack. It does not include the furnace wiring harness, the gas valve, the igniter or the control board, because those are separate parts of the furnace.\u003c\/p\u003e\n\n\u003cdiv style=\"margin-top:24px;padding:16px 18px;background:#f0fdf4;border:1px solid #bbf7d0;border-radius:6px;\"\u003e\n\u003ch3 style=\"margin:0 0 10px 0;font-size:15px;color:#166534;\"\u003e📊 Sail Switch, Limit Switch or Gas Valve — Which One Is Open?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 10px 0;font-size:13px;color:#374151;line-height:1.7;\"\u003eThree different safety devices in the same furnace produce the same \"blower runs, no heat\" complaint. They are not interchangeable, and replacing the wrong one is the most common wasted repair on an RV furnace.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:22%;\"\u003eDevice\u003c\/th\u003e\n\u003cth style=\"width:20%;\"\u003eWhat It Senses\u003c\/th\u003e\n\u003cth style=\"width:19%;\"\u003eContacts at Rest\u003c\/th\u003e\n\u003cth\u003eTypical Symptom When It Fails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSail switch (36680)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAirflow from the blower\u003c\/td\u003e\n\u003ctd\u003eOpen — closes only with air moving\u003c\/td\u003e\n\u003ctd\u003eBlower runs, igniter clicks, burner lights then dies, or no ignition at all\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver-temperature at the heat exchanger\u003c\/td\u003e\n\u003ctd\u003eClosed — opens when too hot\u003c\/td\u003e\n\u003ctd\u003eFurnace runs, then shuts down mid-cycle and will not restart until it cools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 V command from the control board\u003c\/td\u003e\n\u003ctd\u003eClosed — opens on command\u003c\/td\u003e\n\u003ctd\u003eIgniter clicks repeatedly with no flame, and you smell no gas at the burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:10px 0 0 0;font-size:12px;color:#166534;\"\u003eA sail switch that reads open at rest is normal. A sail switch that reads open with the blower running and the paddle lifted by hand is not — that is the one to replace with this 36680.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-top:30px;padding:18px 20px;background:#f0f5ff;border:1px solid #c7dafe;border-radius:6px;\"\u003e\n  \u003ch3 style=\"margin:0 0 12px 0;font-size:16px;color:#1e3a8a;\"\u003e📦 Related Products \u0026amp; Guides\u003c\/h3\u003e\n  \u003cp style=\"margin:0 0 4px 0;font-weight:600;color:#374151;\"\u003e🛒 Other Atwood RV gas-appliance parts we stock:\u003c\/p\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;margin:0 0 12px 0;\"\u003e\n    \u003ca href=\"\/products\/ifjf-93866-water-heater-thermal-cutoff-switch-kit-for-rv-atwood-camper-gas-water-heater\" style=\"flex:1 1 100%;display:flex;align-items:flex-start;gap:10px;text-decoration:none;color:inherit;padding:8px 0;border-top:1px solid #dbeafe;\"\u003e\n      \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/3836\/3894\/files\/1_687a9e5b-106a-4a85-b3d8-28e65eac5c1b.jpg?width=200\" alt=\"iFJF 93866 Water Heater Thermal Cutoff Switch Kit For RV Atwood Camper Gas Water Heater\" loading=\"lazy\" width=\"76\" height=\"76\" style=\"flex:0 0 auto;width:76px;height:76px;object-fit:contain;border:1px solid #e5e7eb;border-radius:6px;background:#fff;padding:4px;\"\u003e\n      \u003cspan style=\"flex:1 1 auto;font-size:13.5px;line-height:1.65;\"\u003e\n        \u003cspan style=\"font-weight:600;color:#1d4ed8;\"\u003e93866 Thermal Cutoff Switch Kit ($23.99)\u003c\/span\u003e\u003cbr\u003e\n        \u003cspan style=\"color:#374151;\"\u003eFits: Atwood RV gas water heaters — the water heater's thermal safety cutoff, not a furnace part.\u003c\/span\u003e\n      \u003c\/span\u003e\n    \u003c\/a\u003e\n    \u003ca href=\"\/products\/ifjf-93868-for-atwood-rv-water-heater-parts-rv-spark-sensor-electrode-2-prong\" style=\"flex:1 1 100%;display:flex;align-items:flex-start;gap:10px;text-decoration:none;color:inherit;padding:8px 0;border-top:1px solid #dbeafe;\"\u003e\n      \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0606\/3836\/3894\/files\/1_8f4c279c-172f-45a6-b1a2-749036198e57.png?width=200\" alt=\"93868 For Atwood RV Water Heater Parts, RV Spark \u0026amp; Sensor\" loading=\"lazy\" width=\"76\" height=\"76\" style=\"flex:0 0 auto;width:76px;height:76px;object-fit:contain;border:1px solid #e5e7eb;border-radius:6px;background:#fff;padding:4px;\"\u003e\n      \u003cspan style=\"flex:1 1 auto;font-size:13.5px;line-height:1.65;\"\u003e\n        \u003cspan style=\"font-weight:600;color:#1d4ed8;\"\u003e93868 RV Spark \u0026amp; Sensor Electrode ($39.99)\u003c\/span\u003e\u003cbr\u003e\n        \u003cspan style=\"color:#374151;\"\u003eFits: Atwood RV gas water heaters — igniter and flame sensor in one part, not a furnace part.\u003c\/span\u003e\n      \u003c\/span\u003e\n    \u003c\/a\u003e\n  \u003c\/div\u003e\n  \u003cp style=\"margin:10px 0 0 0;font-size:13px;color:#374151;\"\u003eThese are water-heater parts, not furnace parts — check the fit line under each name before adding one. Browse more \u003ca href=\"\/collections\/rv-parts\"\u003eRV parts and generator accessories\u003c\/a\u003e, or read the cross-reference table below.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-top:30px;padding:18px 20px;background:#fff7ed;border:1px solid #fed7aa;border-radius:6px;\"\u003e\n\u003ch3 style=\"margin:0 0 8px 0;font-size:16px;color:#9a3412;\"\u003e🔄 36680 Cross Reference \u0026amp; Fitment Notes\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:32%;\"\u003eNumber \/ Term\u003c\/th\u003e\n\u003cth\u003eWhat It Is\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e36680\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAtwood sail switch, original part number — the switch this unit replaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31377\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Dometic \/ Atwood service number for the same sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e35050 \/ 35052 \/ 35054 \/ 35137\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier Hydro Flame sail switch numbers that cross to 36680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e36133 \/ 37716\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntermediate service numbers that cross to 36680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSail switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlso listed as an airflow switch or \"sail\" switch — same device, sold by function on some pages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimit switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature safety device — \u003cstrong\u003enot\u003c\/strong\u003e interchangeable with this sail switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgniter \/ spark electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate ignition part — replacing it will not fix an airflow fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0 0 0;font-size:12px;color:#7c2d12;\"\u003eAtwood, Hydro Flame and Dometic are trademarks of their respective owners and are referenced here only to identify the furnaces and part numbers this switch fits. This is an iFJF aftermarket sail switch, not a genuine Atwood or Dometic part. It does not include the furnace, the blower, the gas valve, the igniter or the wiring harness.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#f0f7ff;border:1px solid #b8d4f0;border-radius:6px;padding:16px;margin-top:20px;\"\u003e\n\u003cstrong\u003eNot sure your furnace takes a 36680?\u003c\/strong\u003e Send us a photo of the furnace rating plate and the switch you are removing, with the wiring visible. Our team will confirm the match before you order.\u003cbr\u003e\n\u003cstrong\u003eEmail:\u003c\/strong\u003e support@ifjf.com\u003cbr\u003e\n\u003cspan style=\"font-size:0.9em;\"\u003eBacked by \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eIATF 16949:2016\u003c\/strong\u003e quality management system certifications.\u003c\/span\u003e\n\u003c\/div\u003e\n","brand":"iFJF","offers":[{"title":"Default Title","offer_id":52475541487862,"sku":"FJ-X-SS06-GY","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/3836\/3894\/files\/8cc68f89ee4372be597b20da43a8b114.jpg?v=1795414071","url":"https:\/\/ifjf.net\/products\/36680-atwood-rv-sail-switch","provider":"iFJF Direct","version":"1.0","type":"link"}