{"product_id":"4655-manual-humidistat-control","title":"4655 Manual Humidistat Control for Whole-House Duct Humidifiers","description":"\n\u003ch2\u003e4655 Manual Humidistat Control for Whole-House Duct Humidifiers — 24 VAC, 2-Wire, 15%–45% RH Dial\u003c\/h2\u003e\n\u003cp\u003eThe iFJF 4655 manual humidistat is the \u003cstrong\u003etwo-wire, 24 VAC dial control\u003c\/strong\u003e that switches a whole-house humidifier on and off to hold the indoor humidity you set. It is the control sold as \u003cstrong\u003eAprilAire 4655\u003c\/strong\u003e, and it fits the \u003cstrong\u003e400, 500, 600 and 700 series\u003c\/strong\u003e humidifiers — including the M, MK, MZ and MKZ versions of each — plus \u003cstrong\u003e800 series steam humidifiers\u003c\/strong\u003e on a 24 VAC control circuit. Two wires in, no polarity, no programming: mount it on a living-space wall or on the return duct, turn the pointer to the mark that matches today’s outdoor temperature, and the humidifier runs whenever the furnace blower runs.\u003c\/p\u003e\n\u003cp\u003eThe dial face is printed with \u003cstrong\u003eoutdoor temperatures, not just percentages\u003c\/strong\u003e: −20°F lines up with 15% RH, 0°F with 25%, +20°F with 35%, and a 45% setting covers mild weather. That is the whole point of a manual humidistat — cold air holds less moisture before windows sweat, so the control has to be told what it is like outside. Inside the housing a moisture-sensitive ribbon with a sponge pad expands as indoor humidity rises and opens the switch, then contracts as the air dries and closes it again. The result is a dry-contact closure that cycles the humidifier’s 24 VAC solenoid valve, which is how every control in this family works.\u003c\/p\u003e\n\u003cp\u003eReplace the control when the humidifier stops running although the dial is calling for humidity, when it runs continuously and the windows sweat, or when the control switch behind the knob has discoloured from years of heat. It is a five-minute swap onto the same two low-voltage wires.\u003c\/p\u003e\n\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExact 4655 Replacement:\u003c\/strong\u003e Same footprint, same two-screw wall or duct mounting and the same two-wire terminals as the AprilAire 4655 control it replaces — no adapter plate, no new holes in most installs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15%–45% RH Dial with Outdoor-Temperature Marks:\u003c\/strong\u003e −20°F → 15%, 0°F → 25%, +20°F → 35%, plus a 45% setting for mild weather, so you set humidity the way the dial was designed to be read.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24 VAC Low-Voltage Only:\u003c\/strong\u003e Runs on the Class 2 control circuit that already feeds the humidifier solenoid. No line voltage enters the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Wire, Non-Polarized:\u003c\/strong\u003e Either lead goes on either terminal. No matching, no jumper and no transformer of its own to fail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Ribbon Sensing:\u003c\/strong\u003e The sensing element needs no battery, no calibration routine and no app — it keeps its setting through power interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWall or Return-Duct Mount:\u003c\/strong\u003e Mount in the living space, or on the return duct at least 6 inches upstream of the humidifier when the ductwork is the closer run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF Position for Summer:\u003c\/strong\u003e Turn the dial past 15% to OFF and the humidifier stays closed through the cooling season without pulling the water line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhite Protective Cover and Knob:\u003c\/strong\u003e The cover hides the terminals and wipes clean; the white plastic housing blends into ductwork and drywall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:34%;\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eBenefit (What It Means for You)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor-temperature dial scale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYou set humidity by matching today’s outdoor temperature instead of guessing a percentage — the single change that stops window condensation in a cold snap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTwo-wire non-polarized terminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThere is no wrong way to connect it. Either lead to either screw, so a DIY swap cannot be reversed and cannot damage the control.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDry-contact closure for the 24 VAC solenoid\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitches the humidifier water valve directly, with no relay in between to corrode or chatter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical ribbon-and-sponge sensing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHolds its setting through brown-outs and power cuts — nothing to re-program when the furnace breaker is reset.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSame 2-screw mounting pattern\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReuses the holes left by the control you remove, so the wall or duct is not drilled twice.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeparate OFF position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShuts the humidifier down for the season in one turn, without touching the saddle valve or the wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003ch3 id=\"compatibility\"\u003eCompatibility \u0026amp; Cross-Reference\u003c\/h3\u003e\n\u003cdiv style=\"font-size:0.95em;color:#555;margin-bottom:8px;\"\u003eFits whole-house humidifiers that use a \u003cstrong\u003emanual dial humidistat on a 24 VAC, two-wire circuit\u003c\/strong\u003e. Match the series on your humidifier’s model plate against the table below before ordering.\u003c\/div\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:34%;\"\u003eSeries\u003c\/th\u003e\n\u003cth\u003eModels Covered\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAprilAire 400 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400, 400M, 400MK, 400MZ, 400MKZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAprilAire 500 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500, 500M, 500MK, 500MZ, 500MKZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAprilAire 600 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600, 600M, 600MK, 600MZ, 600MKZ, 620M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAprilAire 700 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700, 700M, 700MZ, 700MKZ, 720M, 720MKZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAprilAire 800 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 steam humidifier, on a 24 VAC dry-contact control circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4\u003eCommon Applications:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBypass whole-house humidifiers on a forced-air furnace — 400 and 500 series\u003c\/li\u003e\n\u003cli\u003eFlow-through and fan-powered humidifiers — 600 and 700 series\u003c\/li\u003e\n\u003cli\u003eSteam humidifiers wired to a 24 VAC dry-contact control — 800 series\u003c\/li\u003e\n\u003cli\u003eRetrofit where the original manual control is stuck open, stuck closed or discoloured\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"background:#fff8e1;border:1px solid #ffe082;border-radius:4px;padding:12px;margin:12px 0;\"\u003e\n\u003cstrong\u003e⚠️ 24 VAC only — never connect this control to 120 V or 240 V.\u003c\/strong\u003e Before ordering, check two things on the control you are removing: that it has \u003cstrong\u003eexactly two low-voltage wires\u003c\/strong\u003e, and that the humidifier is switched by a \u003cstrong\u003emanual dial\u003c\/strong\u003e. If your unit uses an automatic digital control with an outdoor sensor, or the existing control has more than two wires, send us a photo of the wiring and the model plate and we will confirm the match first.\n\u003c\/div\u003e\n\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:42%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4655\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eManual (mechanical) humidistat — dial with OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC, Class 2 low voltage only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003c\/td\u003e\n\u003ctd\u003e2-wire, non-polarized dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Setting Range\u003c\/td\u003e\n\u003ctd\u003e15% to 45% RH, plus OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor Temperature Marks\u003c\/td\u003e\n\u003ctd\u003e−20°F → 15% · 0°F → 25% · +20°F → 35%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Element\u003c\/td\u003e\n\u003ctd\u003eMoisture-sensitive ribbon with sponge pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eLiving-space wall or return duct, at least 6 in upstream of the humidifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eWhite plastic with knob and protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 5.12\" × 3.03\" × 0.83\" (130 × 77 × 21 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncludes\u003c\/td\u003e\n\u003ctd\u003e1 × 4655 manual humidistat control (knob and cover fitted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality\u003c\/td\u003e\n\u003ctd\u003eiFJF Quality Guarantee\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eKill power at the furnace.\u003c\/strong\u003e Open the breaker feeding the furnace or air handler. The 24 VAC control circuit is fed from the transformer inside that unit, so turning the thermostat off is not enough.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm it is a 2-wire, 24 VAC circuit.\u003c\/strong\u003e With a multimeter across the two wires at the old control you should read roughly 24 VAC. Two wires, low voltage — that is the only wiring this control accepts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePick the location.\u003c\/strong\u003e A living-space wall or the return duct, at least 6 inches upstream of the humidifier. Avoid outside walls, direct sun, supply registers and doorways, because a humidistat reads the air right around it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReuse the mounting holes.\u003c\/strong\u003e Hold the new control against the old screw pattern before drilling anything. If you must drill, anchor the base level and feed the two wires through the back opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect either wire to either terminal.\u003c\/strong\u003e Polarity does not matter. Use the existing wire nuts or the terminals on the base, and seal the wall penetration so attic or crawlspace air does not skew the reading.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the dial by outdoor temperature.\u003c\/strong\u003e Match the pointer to today’s outdoor temperature mark (−20°F, 0°F or +20°F). Colder outside means a lower indoor humidity setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest with the furnace running.\u003c\/strong\u003e Call for heat so the blower starts: the humidifier solenoid should open and water should flow. If the windows sweat, turn the dial one mark colder and give it a day; if the house feels dry and static, one mark warmer.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Will this 4655 humidistat work with my AprilAire humidifier?\u003c\/h4\u003e\n\u003cp\u003eA: It replaces the manual dial control on AprilAire 400, 500, 600 and 700 series humidifiers, including the M, MK, MZ and MKZ versions, plus the 800 series steam humidifier when it is switched by a 24 VAC dry-contact control. Check the model number on the humidifier's rating plate against the compatibility table above. If the plate shows a number that is not in the table, send us a photo before ordering and we will confirm it.\u003c\/p\u003e\n\u003ch4\u003eQ: Is this control 24 volts or line voltage?\u003c\/h4\u003e\n\u003cp\u003eA: It is 24 VAC, Class 2 low voltage only. The control switches the low-voltage solenoid valve on the humidifier; it must never be connected to 120 V or 240 V. The 24 VAC comes from the transformer inside your furnace or air handler, which is also why the humidifier only runs when that unit is powered.\u003c\/p\u003e\n\u003ch4\u003eQ: Does it matter which wire goes on which terminal?\u003c\/h4\u003e\n\u003cp\u003eA: No. This is a dry-contact switch with two non-polarized leads, so either wire can go on either terminal. That is also why the swap is safe for a first-time installer: there is no reversed wiring path that can damage the control.\u003c\/p\u003e\n\u003ch4\u003eQ: Where should I mount the humidistat?\u003c\/h4\u003e\n\u003cp\u003eA: On an interior wall in the living space, or on the return duct at least 6 inches upstream of the humidifier. Avoid exterior walls, direct sunlight, supply registers and doorways. A humidistat senses the air immediately around it, so a bad location produces condensation in one room and dry air in the rest of the house no matter how the dial is set.\u003c\/p\u003e\n\u003ch4\u003eQ: How do I set the dial correctly?\u003c\/h4\u003e\n\u003cp\u003eA: Turn the pointer to the mark that matches the current outdoor temperature: minus 20 F aligns with 15% RH, 0 F with 25%, and plus 20 F with 35%. Then correct by observation - if windows sweat, move one mark toward the colder position; if the house feels dry or you get static shocks, move one mark toward the warmer position, and give each change about a day.\u003c\/p\u003e\n\u003ch4\u003eQ: The humidifier does not run even with the dial turned up. What should I check?\u003c\/h4\u003e\n\u003cp\u003eA: Confirm the thermostat is calling for heat and the furnace blower is running, because most humidifiers only operate with the blower on. Then check the saddle valve is open, the solenoid clicks and water flows, and that 24 VAC is present at the two control wires. If the solenoid has voltage but no water passes, the valve or the water panel is the problem, not the humidistat.\u003c\/p\u003e\n\u003ch4\u003eQ: Is this a digital control with a display?\u003c\/h4\u003e\n\u003cp\u003eA: No. The 4655 is a mechanical dial humidistat: the pointer position is the setting, there is no display, no battery and no app. Some listings describe it as digital, but the unit has a dial, an OFF position and a ribbon sensing element, which is what makes it a drop-in replacement for the manual control already on your duct.\u003c\/p\u003e\n\n\u003ch3\u003e📊 Manual 4655 vs an Automatic Digital Control\u003c\/h3\u003e\n\u003cp\u003eBoth switch the same 24 VAC solenoid. The difference is who decides the humidity level — you, or an outdoor sensor.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:26%;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"width:37%;\"\u003eiFJF 4655 (Manual)\u003c\/th\u003e\n\u003cth\u003eAutomatic Digital Control\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetting method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDial matched to outdoor temperature\u003c\/td\u003e\n\u003ctd\u003eSet point entered on a keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot used — you read the weather\u003c\/td\u003e\n\u003ctd\u003eWired sensor adjusts automatically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring at the control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 wires, non-polarized\u003c\/td\u003e\n\u003ctd\u003e2 wires plus sensor leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower interruptions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeeps its setting mechanically\u003c\/td\u003e\n\u003ctd\u003eReturns to stored set point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay \/ battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eLCD, needs power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReplacing a failed or discoloured manual control\u003c\/td\u003e\n\u003ctd\u003eNew install, or upgrade from manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:0.92em;color:#555;\"\u003eIf your humidifier already has an automatic control with an outdoor sensor, this 4655 is not a like-for-like swap — the sensor wiring has nowhere to land. Send us a photo of your existing control before ordering and we will point you to the right part.\u003c\/p\u003e\n\n\n\u003ch3\u003e📦 Related Products \u0026amp; Guides\u003c\/h3\u003e\n\u003cp\u003eParts our customers pair with a humidistat swap on a forced-air system.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:44%;\"\u003eProduct\u003c\/th\u003e\n\u003cth style=\"width:40%;\"\u003eFits\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/ifjf-57t01-843-blower-time-delay-relay-replacement-for-91-9301-c800924p01-rly02807-x13260259010-rly02257-57t01-843-24v-post-purge-fan-delay-control\"\u003e57T01-843 Blower Time Delay Relay\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V HVAC post-purge fan control\u003c\/td\u003e\n\u003ctd\u003e$69.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/rhi-112a-temperature-and-humidity-sensor-module-for-measuring-environmental-temperature-and-humidity-levels\"\u003eRHI-112A Temperature \u0026amp; Humidity Sensor Module\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor humidity monitoring for HVAC setups\u003c\/td\u003e\n\u003ctd\u003e$27.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eBrowse more \u003ca href=\"\/collections\/electronics\"\u003eHVAC controls and electronics\u003c\/a\u003e we stock, or read the full compatibility table above before you order.\u003c\/p\u003e\n\n\n\u003ch3\u003e🔄 4655 Cross Reference \u0026amp; Fitment Notes\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:36%;\"\u003eNumber \/ Series\u003c\/th\u003e\n\u003cth\u003eWhat It Is\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4655\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAprilAire manual 2-wire humidistat — the control this unit replaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4655 Manual Humidistat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSame control listed by function rather than number on some retailer pages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e400 \/ 500 \/ 600 \/ 700 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAprilAire humidifiers that use the 4655 manual dial control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e800 Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAprilAire steam humidifier, when switched by a 24 VAC dry-contact control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e60 \/ 62 Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic digital controls — \u003cstrong\u003enot\u003c\/strong\u003e interchangeable with this manual dial unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:0.9em;color:#555;\"\u003eAprilAire and the model numbers above are referenced for identification only and remain the property of their owners. This is an iFJF aftermarket manual humidistat, not a genuine AprilAire part. It switches a 24 VAC humidifier solenoid; it does not include the humidifier, the solenoid valve, the transformer or the water panel.\u003c\/p\u003e\n\n\n\u003cdiv style=\"background:#f0f7ff;border:1px solid #b8d4f0;border-radius:6px;padding:16px;margin-top:20px;\"\u003e\n\u003cstrong\u003eNot sure your humidifier takes a 4655?\u003c\/strong\u003e Send us a photo of the control you are removing with the wiring visible, plus the model number from the humidifier’s rating plate. Our team will confirm the match before you order.\u003cbr\u003e\n\u003cstrong\u003eEmail:\u003c\/strong\u003e support@ifjf.com\u003cbr\u003e\n\u003cspan style=\"font-size:0.9em;\"\u003eBacked by \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eIATF 16949:2016\u003c\/strong\u003e quality management system certifications.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#f7f7f7;border:1px solid #e0e0e0;border-radius:6px;padding:14px 18px;margin-top:18px;\"\u003e\n\u003cstrong\u003e📖 Related Guides\u003c\/strong\u003e\n\u003cul style=\"margin:8px 0 0 18px;\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/blogs\/news\/why-whole-house-humidifier-needs-humidistat\"\u003e4655 Humidistat: Why Every Whole-House Humidifier Needs One\u003c\/a\u003e — what a humidistat actually does, how to set the dial by outdoor temperature, and how to tell a dead control from a dead humidifier.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/blogs\/news\/whole-house-humidifier-not-working-diagnosis\"\u003eWhole-House Humidifier Not Working? 6-Step Diagnosis\u003c\/a\u003e — the system sequence to work through when the house stays dry: damper, blower, water path, 24 VAC solenoid test, and water panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"iFJF","offers":[{"title":"Default Title","offer_id":52459166990582,"sku":"FJ-X-MX4655","price":47.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/3836\/3894\/files\/4655-manual-humidistat-01.jpg?v=1795235967","url":"https:\/\/ifjf.net\/products\/4655-manual-humidistat-control","provider":"iFJF Direct","version":"1.0","type":"link"}