{"product_id":"903429-furnace-control-board-nordyne-m1","title":"903429 903429A Furnace Control Board for Intertherm M1M — Fits 624602","description":"\u003ch2\u003e903429 903429A Furnace Control Board for Intertherm M1M — Fits 624602\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e903429\u003c\/strong\u003e integrated furnace control board is a direct replacement control for Nordyne-platform \u003cstrong\u003eM1 series\u003c\/strong\u003e gas furnaces built for manufactured and mobile homes — the Intertherm, Miller, Nordyne, Nortek, Revolv and Broan units that used board number 903429 (later revised to 903429A) or any of the earlier numbers \u003cstrong\u003e624602, 6246020, 624602-0, 624602A, 624602B, 624640 and 624640-A\u003c\/strong\u003e. It runs on 120 VAC line power with a 24 VAC thermostat circuit, sequences the inducer, hot surface igniter, gas valve and blower on every call for heat, and reports faults through the on-board red and yellow diagnostic LEDs. The board measures 5 × 1.1 × 5.5 in and weighs 8.8 oz (249 g), so it drops onto the original standoffs inside the M1 furnace control compartment.\u003c\/p\u003e\n\u003ch3\u003e📋 Key Takeaways\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eDirect Replacement:\u003c\/strong\u003e Replaces 903429 and the revised 903429A across Nordyne M1 series gas furnaces.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eFull Cross-Reference:\u003c\/strong\u003e Also covers 624602, 6246020, 624602-0, 624602A, 624602B, 624640 and 624640-A.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eM1 M Series Coverage:\u003c\/strong\u003e Fits M1MA \/ M1MB \/ M1MC \/ M1MD (056, 070, 077, 090) and M1GB \/ M1GC \/ M1GD \/ M1GH (056, 070, 077, 090) cabinets.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003e120 VAC Line \/ 24 VAC Control:\u003c\/strong\u003e 120 VAC 60 Hz input with an 18–30 VAC thermostat circuit — the same electrical arrangement as the original control.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eHot Surface Ignition:\u003c\/strong\u003e Drives the 6.0 A igniter, proves flame through the flame sensor and holds the gas valve closed (0.5 A @ 24 VAC) when proof is lost.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eRed + Yellow LED Diagnostics:\u003c\/strong\u003e Flash codes separate a limit, pressure-switch, flame-sense, ignition-lockout or grounding fault before any part is swapped.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eCheck Before You Order:\u003c\/strong\u003e Read the number silkscreened on the old board — this is an M1-platform control, not a universal board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003cth style=\"width: 35%;\"\u003eFeature\u003c\/th\u003e\n\u003cth\u003eBenefit (What It Means for You)\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eIntegrated control (IFC) for M1 furnaces\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eOne board runs the whole heating sequence — inducer proof, hot surface igniter warm-up, gas valve timing, blower on delay and cool-down — so the furnace behaves exactly as it did with the factory control.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eReplaces 903429 \/ 903429A, 624602, 624640 family\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eA furnace whose data plate or parts list shows any of those numbers uses this board, which takes the guesswork out of matching an earlier revision to the current one.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003e120 VAC line, 24 VAC control circuit\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eStandard manufactured-home furnace voltages with the original terminal designations, so the thermostat, gas valve, inducer and blower wires transfer connector by connector without modification.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eHot surface ignition with flame sensing\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eThe board heats the igniter, opens the gas valve only after the ignition window, and shuts the valve the moment flame proof is lost — the safety behaviour unburned gas depends on.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eRed and yellow diagnostic LEDs\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eA red flash code names the fault the board has latched (limit open, pressure switch, ignition lockout, reversed polarity or bad ground) and the yellow LED shows flame signal strength, so diagnosis starts at the board.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eDrop-in mounting on the original standoffs\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eThe four white standoffs and the molex \/ push-on terminal layout match the M1 compartment, so no bracket, drilling or harness adapter is needed.\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 id=\"compatibility\"\u003eCompatibility \u0026amp; Cross-Reference\u003c\/h3\u003e\n\u003ch4\u003eReplaces \/ Interchange Part Numbers\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003cth style=\"width: 42%;\"\u003eInterchange Part Number\u003c\/th\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e903429\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBoard number of this replacement (Nordyne \/ Nortek integrated control, M1 series)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e903429A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLater revision of 903429 — same form, fit and function\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e624602\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEarlier M1 control number carried on parts lists\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6246020 \/ 624602-0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariant spellings of the 624602 number\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e624602A \/ 624602B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRevision letters of the 624602 control\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e624640 \/ 624640-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM1 control number used on later production runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4\u003eHoneywell-Built OEM Numbers for the Same Board\u003c\/h4\u003e\n\u003cp\u003eNordyne had this control built by Honeywell, so the board also carries Honeywell numbers. They look like different parts but they are the same 1012-958 board written at three levels of detail — the middle segment is a production \/ revision code, not a different board:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003cth style=\"width: 42%;\"\u003eHoneywell Number\u003c\/th\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1012-958 \/ 1012-958A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort form printed on the board and quoted in Nordyne parts lists\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1012-93-9581A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong form: the 93 segment is a revision code, 958 is the board, A the change level\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1012-012-958A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong form with a different revision prefix — the 958 board is unchanged\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e233089\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNordyne internal stocking number for the same control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eSo a board marked \u003cstrong\u003e903429\u003c\/strong\u003e, \u003cstrong\u003e903429A\u003c\/strong\u003e, \u003cstrong\u003e624602\u003c\/strong\u003e, \u003cstrong\u003e624640\u003c\/strong\u003e or \u003cstrong\u003e1012-958A\u003c\/strong\u003e is the same part written differently. If the number on your board is not in either table above, it is a different control and this board will not fit.\u003c\/p\u003e\n\u003ch4\u003eCommon Applications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eNordyne M1M series gas furnaces — M1MA, M1MB, M1MC and M1MD cabinets in 056, 070, 077 and 090 input sizes, for example M1MB 070A BW and M1MC 090A AW\u003c\/li\u003e\n  \u003cli\u003eNordyne M1G series gas furnaces — M1GB, M1GC, M1GD and M1GH cabinets in 056, 070, 077 and 090 input sizes\u003c\/li\u003e\n  \u003cli\u003eManufactured home, mobile home and park model installations where the furnace sits in a closet or alcove with a roof-jack vent\u003c\/li\u003e\n  \u003cli\u003eFurnaces sold under the Intertherm, Miller, Nordyne, Nortek, Revolv and Broan names on the same M1 platform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is a Nordyne M1-platform control, not a universal board. Read the number printed on your old board before ordering: if it matches any number in the table above, this board is the replacement. A board from another manufacturer will not interchange even when the connector count looks similar.\u003c\/p\u003e\n\u003ch3 id=\"led-codes\"\u003eRed \u0026amp; Yellow LED Diagnostic Codes\u003c\/h3\u003e\n\u003cp\u003eThe board reports through two LEDs. Count the red flashes, then check the yellow LED for flame signal:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003cth style=\"width: 18%;\"\u003eLED\u003c\/th\u003e\n\u003cth style=\"width: 32%;\"\u003eIndication\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eSteady ON\u003c\/td\u003e\n\u003ctd\u003eControl OK — board is powered and the internal check passed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eSteady OFF\u003c\/td\u003e\n\u003ctd\u003eNo power to the board — check the 120 VAC supply, the furnace switch and the board fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003eRapid flash\u003c\/td\u003e\n\u003ctd\u003eFalse flame or internal control fault\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003e1 flash\u003c\/td\u003e\n\u003ctd\u003eLimit switch is open\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003e2 flashes\u003c\/td\u003e\n\u003ctd\u003ePressure switch is open with the inducer running\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003e3 flashes\u003c\/td\u003e\n\u003ctd\u003ePressure switch is closed with the inducer off\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003e4 flashes\u003c\/td\u003e\n\u003ctd\u003eLockout due to failed ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003ctd\u003e5 flashes\u003c\/td\u003e\n\u003ctd\u003e115 VAC line and neutral reversed, or no ground\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003ctd\u003eSteady ON\u003c\/td\u003e\n\u003ctd\u003eGood flame signal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003ctd\u003eBlinking\u003c\/td\u003e\n\u003ctd\u003eWeak flame signal — clean or reposition the flame sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003ctd\u003eSteady OFF\u003c\/td\u003e\n\u003ctd\u003eNo flame signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e903429 (replaces 903429A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated furnace control (IFC), single stage\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eFurnace Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNordyne M1 series — M1M and M1G cabinets\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VAC thermostat circuit (18–30 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot surface ignition, 6.0 A @ 120 VAC igniter output\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eGas Valve Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A @ 24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eInducer Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/100 HP, 0.69 A @ 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eBlower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/5 HP (or 1\/8 HP), 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed flash code + yellow flame signal LED, 3 A on-board fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eReplaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e903429, 903429A, 624602, 6246020, 624602-0, 624602A, 624602B, 624640, 624640-A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eAlso Crosses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1012-958, 1012-958A, 1012-93-9581A, 1012-012-958A, 233089 (Honeywell-built OEM numbers)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 × 1.1 × 5.5 in (127 × 28 × 140 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 oz (249 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × 903429 integrated furnace control board\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eiFJF Quality Guarantee\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eCut power at the furnace switch or breaker and shut off the gas supply. Confirm 0 V at the board with a meter before touching a connector.\u003c\/li\u003e\n  \u003cli\u003ePhotograph every molex plug and push-on terminal before removal — the M1 compartment is tight and the harness has no spare length.\u003c\/li\u003e\n  \u003cli\u003eSqueeze the four white standoffs while lifting the old board off, then press the new board onto the same standoffs from the outside edge only.\u003c\/li\u003e\n  \u003cli\u003eReconnect one plug at a time to the identically marked terminal, restore power and watch one complete heat cycle: inducer, igniter, gas valve, blower.\u003c\/li\u003e\n  \u003cli\u003eIf the on-board 3 A fuse is blown, replace it with a 3 A fuse (Nordyne G32-189) and find the short before powering the furnace again.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cdiv style=\"background:#fff3e0;border:1px solid #ffb74d;border-radius:4px;padding:12px;margin-bottom:16px;\"\u003e\n\u003cstrong\u003eInstallation note:\u003c\/strong\u003e a control board swap on a gas furnace should be performed by a qualified HVAC contractor or licensed electrician. If you are unsure whether this board matches your furnace, message us with the model number from the rating plate before ordering.\u003c\/div\u003e\n\u003cp\u003eNeed help confirming fitment? Our support team answers fitment questions before you order — \u003cstrong\u003esupport@ifjf.com\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhy Choose iFJF?\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eOpen cross-reference:\u003c\/strong\u003e all nine covered numbers (903429, 903429A, 624602, 6246020, 624602-0, 624602A, 624602B, 624640, 624640-A) are printed above — match the old board first.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eSpecification transparency:\u003c\/strong\u003e 120 VAC input, 18–30 VAC control circuit, 6.0 A igniter output and 0.5 A gas valve load are stated openly so they can be compared with your original control.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eEvery board powered up before it ships:\u003c\/strong\u003e each unit is functionally tested for fan control, ignition sequencing and safety interlock.\u003c\/li\u003e\n  \u003cli\u003e✅ \u003cstrong\u003eFactory-direct value:\u003c\/strong\u003e supply straight from the manufacturer, without the OEM dealer-counter markup on a discontinued 903429.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Will the 903429 control board fit my furnace?\u003c\/h4\u003e\n\u003cp\u003eA: The 903429 board is built for Nordyne M1 series gas furnaces used in manufactured and mobile homes, sold as Intertherm, Miller, Nordyne, Nortek, Revolv and Broan. Read the part number on the old board first: if it is 903429, 903429A, 624602, 6246020, 624602-0, 624602A, 624602B, 624640 or 624640-A, this board is the direct replacement. The cross-reference table above lists every covered number.\u003c\/p\u003e\n\u003ch4\u003eQ: Which part numbers does the 903429 board replace?\u003c\/h4\u003e\n\u003cp\u003eA: It replaces 903429 and its later revision 903429A, plus the earlier numbers 624602, 6246020, 624602-0, 624602A, 624602B, 624640 and 624640-A. Nordyne discontinued the original 903429 and issued 903429A as the same board under a new number, so a furnace whose parts list shows either number takes this control.\u003c\/p\u003e\n\u003ch4\u003eQ: What are the electrical specifications of the 903429 board?\u003c\/h4\u003e\n\u003cp\u003eA: The board takes 120 VAC 60 Hz line power and runs an 18-30 VAC thermostat circuit. It drives a hot surface igniter at 6.0 A, a 24 VAC gas valve at 0.5 A, a 1\/100 HP inducer at 0.69 A and a 1\/5 HP (or 1\/8 HP) 120 VAC blower, and it protects the low-voltage side with a 3 A fuse.\u003c\/p\u003e\n\u003ch4\u003eQ: How do I read the diagnostic codes on this board?\u003c\/h4\u003e\n\u003cp\u003eA: The red LED shows control status: steady ON means the board is good, one flash an open limit, two flashes a pressure switch open with the inducer running, three flashes a pressure switch closed with the inducer off, four flashes an ignition lockout, and five flashes reversed line and neutral or a missing ground. The yellow LED shows flame: steady ON is a good signal, blinking is a weak signal, and OFF means no flame detected.\u003c\/p\u003e\n\u003ch4\u003eQ: Is this a genuine Nordyne OEM board?\u003c\/h4\u003e\n\u003cp\u003eA: No. This is an iFJF third-party replacement built to the same 120 VAC input, 24 VAC control, hot surface ignition and terminal layout as the original 903429 \/ 903429A control. It is not sold as a Nordyne or Nortek OEM part, and the price reflects factory-direct supply instead of dealer-counter pricing on a discontinued board.\u003c\/p\u003e\n\u003ch4\u003eQ: How do I install the 903429 control board?\u003c\/h4\u003e\n\u003cp\u003eA: Cut power at the breaker and shut off the gas, then photograph every molex plug and push-on terminal. Squeeze the four white standoffs to release the old board, press the new board onto the same standoffs, and reconnect one plug at a time to the matching terminal. Restore power and watch a full heat cycle. A qualified HVAC technician should do the work if you are not comfortable inside a gas appliance.\u003c\/p\u003e\n\u003ch4\u003eQ: How do I know my old control board is actually the problem?\u003c\/h4\u003e\n\u003cp\u003eA: Typical board failures are no ignition, a blower or inducer that runs continuously, a burner that lights and drops out without a pattern, or a red LED that shows a fault code or stays dark. Check the board fuse, the limit and rollout switches, the pressure switch tubing, the flame sensor and the ground first, because a blown fuse or an open limit produces the same no-heat symptom as a failed board.\u003c\/p\u003e\n\u003ch3\u003eWhich Nordyne Furnace Control Board Do You Need?\u003c\/h3\u003e\n\u003cp\u003eNordyne built several furnace families that look alike but take different controls. Match the model prefix on the rating plate to the board, not the price:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003cth style=\"width: 22%;\"\u003eFurnace Family\u003c\/th\u003e\n\u003cth style=\"width: 30%;\"\u003eBoard\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eM1 series\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#666;\"\u003eM1MA \/ M1MB \/ M1MC \/ M1MD, M1GB \/ M1GC \/ M1GD \/ M1GH\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e903429\u003c\/strong\u003e — this listing\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003e$89.99\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eManufactured-home downflow gas furnaces that used 903429 \/ 624602 \/ 624640 controls\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eG7 \/ M7 series\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#666;\"\u003eG7SA \/ G7SK \/ G7SC \/ G7SL, M7RL\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e920915\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003e$79.99\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003eA different single-stage control — will not interchange with an M1 furnace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eIf your rating plate says M1, the 903429 board in this listing is the one to order. If it says G7 or M7, you need the 920915 board instead — the two controls are not interchangeable.\u003c\/p\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × 903429 integrated furnace control board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Problems with M1 Furnace Control Boards — Solved by iFJF\u003c\/h3\u003e\n\u003cp style=\"font-size:0.95em;color:#666;\"\u003eWe read verified owner reviews of Nordyne M1 replacement boards. Here is what keeps coming up — and how this board addresses it:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr style=\"background:#fafafa;\"\u003e\n\u003cth style=\"width:35%;\"\u003e❌ What Owners Complain About\u003c\/th\u003e\n\u003cth style=\"width:5%;\"\u003e\u003c\/th\u003e\n\u003cth style=\"width:60%;\"\u003e✅ How This Board Addresses It\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003e“It says compatible but my furnace did not work”\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#888;\"\u003e— the #1 cause of returns in this category\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd style=\"text-align:center;vertical-align:top;padding:10px;\"\u003e→\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003eBoard number listed before the price\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003e903429, 903429A, 624602 and 624640 are printed in the cross-reference table, so the old board is matched before ordering. This is an M1-platform control, not a universal board.\u003c\/span\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003e“The blower runs but there is no heat”\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#888;\"\u003e— often a flame-sense or limit fault, not the board\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd style=\"text-align:center;vertical-align:top;padding:10px;\"\u003e→\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003eLED code before parts\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003eThe red LED latches the real fault — limit, pressure switch, ignition lockout or ground — so the fuse, limit and flame sensor are checked before the board is condemned.\u003c\/span\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003e“The connectors did not line up with my old board”\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#888;\"\u003e— common when a revision is swapped blind\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd style=\"text-align:center;vertical-align:top;padding:10px;\"\u003e→\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003eSame molex and spade layout\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003eTerminals follow the original 903429 layout and the four white standoffs are in the OEM position, so wiring moves plug by plug from a photographed old board.\u003c\/span\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003e“It failed a month after install”\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.85em;color:#888;\"\u003e— usually heat, vibration or a shorted low-voltage circuit\u003c\/span\u003e\n\u003c\/td\u003e\n    \u003ctd style=\"text-align:center;vertical-align:top;padding:10px;\"\u003e→\u003c\/td\u003e\n    \u003ctd style=\"padding:10px;vertical-align:top;\"\u003e\n\u003cstrong\u003ePower-tested, fused and sealed\u003c\/strong\u003e\u003cbr\u003e\u003cspan style=\"font-size:0.9em;\"\u003eEvery board runs a functional test of fan control, ignition sequencing and safety interlock before shipping, and the 3 A fuse protects the control side from a shorted thermostat wire.\u003c\/span\u003e\n\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003e📦 Related Furnace Control Boards\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x:auto;clear:both;width:100%;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;table-layout:fixed;word-wrap:break-word;\"\u003e\n  \u003ctr\u003e\n\u003cth style=\"width: 52%;\"\u003eBoard\u003c\/th\u003e\n\u003cth style=\"width: 28%;\"\u003eFits\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/920915-furnace-control-board-nordyne-g7-m7-replaces-624742\"\u003e920915 Furnace Control Board for Nordyne G7 M7\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNordyne G7 \/ M7, KG7, FG7\u003c\/td\u003e\n\u003ctd\u003e$79.99\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/031-01267-001a-furnace-control-board\"\u003e031-01267-001A Furnace Control Board 120V HSI for York Luxaire Coleman\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eYork, Luxaire, Coleman 031-01267-001A\u003c\/td\u003e\n\u003ctd\u003e$89.99\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/50a55-843-furnace-control-board-compatible-white-rodgers-lennox\"\u003e50A55-843 Furnace Control Board Compatible with White-Rodgers Lennox\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite-Rodgers 50A55-843, Lennox\u003c\/td\u003e\n\u003ctd\u003e$137.99\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/1012-925c-furnace-control-board-24-vac-hsi-compatible-rheem-ruud\"\u003e1012-925C Furnace Control Board 24 VAC HSI Compatible with Rheem Ruud\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRheem \/ Ruud 1012-925C\u003c\/td\u003e\n\u003ctd\u003e$179.99\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/1170063-furnace-control-board-replaces-1138-200-icp-furnaces\"\u003eiFJF 1170063 Furnace Control Board - Replaces 1138-200 ICP Furnaces\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eICP 1170063 \/ 1138-200\u003c\/td\u003e\n\u003ctd\u003e$177.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eEach board in the table above fits a different furnace family — the shared 24 VAC single-stage architecture does not make them interchangeable, so confirm the number on your old board before ordering.\u003c\/p\u003e\n\u003cp style=\"margin-top:12px;\"\u003e📂 \u003cstrong\u003eBrowse More:\u003c\/strong\u003e \u003ca href=\"\/collections\/electronics\"\u003eAll Electronics Products →\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e🔄 Cross Reference\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e903429\u003c\/strong\u003e = \u003cstrong\u003e903429A\u003c\/strong\u003e = \u003cstrong\u003e624602\u003c\/strong\u003e = \u003cstrong\u003e6246020\u003c\/strong\u003e = \u003cstrong\u003e624602-0\u003c\/strong\u003e = \u003cstrong\u003e624602A\u003c\/strong\u003e = \u003cstrong\u003e624602B\u003c\/strong\u003e = \u003cstrong\u003e624640\u003c\/strong\u003e = \u003cstrong\u003e624640-A\u003c\/strong\u003e. All nine numbers are printed on Nordyne-platform M1 series gas furnaces; the board in this listing replaces every one of them.\u003c\/p\u003e\n\u003cdiv style=\"background:#f0f7ff;border:1px solid #b8d4f0;border-radius:6px;padding:16px;margin-top:20px\"\u003e\n\u003cstrong\u003eFactory Direct Supply \u0026amp; Wholesale\u003c\/strong\u003e — iFJF is a direct manufacturer of high-performance replacement parts for heating and filtration systems. Custom specifications and bulk orders are highly welcome. Contact us for exclusive dealer pricing and volume discounts. Backed by \u003cstrong\u003eISO 9001:2015\u003c\/strong\u003e and \u003cstrong\u003eIATF 16949:2016\u003c\/strong\u003e quality management system certifications.\u003cbr\u003e\u003cstrong\u003eEmail:\u003c\/strong\u003e support@ifjf.com\u003c\/div\u003e\n","brand":"iFJF","offers":[{"title":"Default Title","offer_id":52448282181878,"sku":"FJ-CB-NOR9034","price":89.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0606\/3836\/3894\/files\/01_96e00187-c19f-4166-ae92-67f2af2e7bc0.jpg?v=1795176426","url":"https:\/\/ifjf.net\/products\/903429-furnace-control-board-nordyne-m1","provider":"iFJF Direct","version":"1.0","type":"link"}