36680 Sail Switch for Atwood Hydro Flame RV Furnace — Replaces 31377

Description

36680 Sail Switch for Atwood Hydro Flame RV Furnace — Gray, 250 VAC Airflow Safety Switch

Product Overview

The iFJF 36680 sail switch is the airflow safety switch that decides whether your Atwood / Hydro Flame RV furnace is allowed to fire. It sits in the blower air stream with a hinged plastic sail: when the blower pushes enough air, the sail lifts, the contacts close and the gas valve opens. When airflow drops — weak blower, blocked duct, low battery — the sail stays down, the contacts stay open and the furnace will not ignite. That is not a fault; it is the switch doing its job before unburned propane can build up in the combustion chamber.

It is a direct replacement for 36680 (the old Atwood SKU) and 31377 (the current Dometic part number), and it also covers 35050, 35052, 35054, 35137, 36133 and 37716. The switch is rated 250 VAC, uses screw terminals on the original two leads, and mounts on the same bracket holes — no wiring change, no adapter. This listing is the gray version, one switch per pack.

Key Features

  • Exact 36680 / 31377 Replacement: Same sail shape, same bracket footprint and the same two screw terminals as the switch you are removing — it drops onto the existing mounting holes in the blower compartment.
  • Eight Interchange Numbers Covered: 36680, 31377, 35050, 35052, 35054, 35137, 36133 and 37716 — the full range of Atwood / Hydro Flame part numbers that cross to this switch.
  • 250 VAC Contact Rating: Rated far above the 12 V DC control circuit it actually switches, so the contacts do not pit from the furnace's inductive load.
  • Normally Open, Closes on Airflow: A true airflow-proving switch — the circuit stays open until the blower actually moves air, which is what makes it a safety device and not just a power switch.
  • Hinged Sail Paddle: The paddle hangs from a hinge pin and lifts at a repeatable air velocity, so it does not chatter at low blower speed or stick open after a season of dust.
  • Screw Terminals, Original Lead Positions: Two spade-style screw terminals take the existing leads. Polarity does not matter for the switch function.
  • Gray Glass-Filled Plastic Housing: The molded housing and metal mounting bracket hold their shape in the heat of a furnace compartment, where a soft plastic switch would warp and jam.
  • One Switch Per Pack: Enough to replace the failed switch in a single furnace — no need to buy a two-pack when only one has failed.

Features & Benefits

Feature Benefit (What It Means for You)
Airflow-proving sail paddle The furnace cannot open the gas valve until the blower actually moves air — the exact condition this switch was designed to enforce.
Crosses to 8 Atwood / Dometic numbers One part covers the older 35050 / 35137 / 37716 furnaces and the current 31377 service number, so you order once instead of guessing which revision your coach was built with.
250 VAC rated contacts Switching a 12 V DC gas-valve circuit through a 250 V AC rated contact set means the points stay clean far longer than a switch rated only for the load.
Normally open at rest With the blower off the circuit is open. A no-heat complaint can be traced with a meter at the switch instead of guessing at the control board.
Same bracket and screw terminals No drilling, no crimping, no new connectors — the swap is a screwdriver job inside the blower compartment.
Heat-stable gray housing Holds its shape and its sail clearance through repeated heat cycles, so the switch does not start sticking in its second or third season.

Compatibility & Cross-Reference

Fits Atwood / Hydro Flame RV furnaces that use the 36680-style sail switch in the blower air stream. Match the model number on your furnace's rating plate against the tables below before ordering.

Replaces These Part Numbers:

Part Number Notes
36680 Original Atwood part number — the number this switch is sold under
31377 Current Dometic / Atwood service number for the same switch
35050 Early Hydro Flame furnace sail switch
35052 Early Hydro Flame furnace sail switch
35054 Early Hydro Flame furnace sail switch
35137 Early Hydro Flame furnace sail switch
36133 Intermediate service number that crosses to 36680
37716 Intermediate service number that crosses to 36680

Furnace Models Covered:

Series Models
1522 Series 1522 2-Stage, 1522 LD 2-Stage, XT-1522
2334 / 2540 2334 2-Stage, 2540 2-Stage
7900 Series 7912-II, 7916-II, 7920-II
8500 Series II 8516-II, 8520-II, 8525-II, 8531-II, 8535-II; 85-II 16-20, 85-II 31-35
8500 Series III 8516-III, 8520-III, 8525-III, 8531-III, 8535-III; 85-III 31-35
8500 Series IV 8516-IV, 8520-IV, 8525-IV, 8531-IV, 8535-IV; 85-IV 16, 85-IV 20, 85-IV 25, 85-IV 31, 85-IV 35
8900 Series 8935-DC-I, 8935-AC-I, 8940-DC-I, 8940-AC-I, 8935-DC-II, 8935-AC-II, 8940-DC-II, 8940-AC-II, 8935-DC-III, 8935-AC-III, 8940-DC-III, 8940-AC-III
Do not bypass this switch to "make the furnace run." Jumpering the two leads will fire the burner whether or not the blower is moving air, which is exactly the condition the switch exists to prevent. If a jumpered furnace runs and a furnace with this switch does not, the problem is airflow — a blocked duct, a collapsed flexible hose, a dirty blower wheel or a battery too low to spin the blower at full speed — not a "bad switch." Fix the airflow first, then fit the new switch.

Specifications

Specification Value
Part Number 36680
Replaces 31377, 35050, 35052, 35054, 35137, 36133, 37716
Switch Type Sail (airflow-proving) switch, SPST normally open
Contact Rating 250 VAC
Circuit Switched Furnace 12 V DC control circuit (gas valve / ignition sequence)
Actuator Hinged sail paddle on mounting bracket
Terminals 2 × screw terminals, existing leads reused
Housing Gray plastic housing with metal mounting bracket
Mounting Position In the furnace blower air stream, paddle facing airflow
Dimensions Approx. 2.5 × 0.5 × 0.31 in (64 × 13 × 8 mm)
Weight Approx. 0.7 oz (20 g)
Includes 1 × 36680 sail switch (gray)
Quality iFJF Quality Guarantee

Installation Tips

  1. Shut the gas off at the cylinder and kill the 12 V feed. Close the propane valve at the tank or at the manifold, then pull the furnace fuse or switch the coach battery disconnect. The blower will still spin on residual power long enough to surprise you.
  2. Open the furnace access panel. On most Atwood / Hydro Flame installations the sail switch sits on the blower housing, downstream of the blower wheel, with two leads running to it. Follow the wires rather than guessing at the part.
  3. Photograph the wiring before you disconnect it. The switch itself is not polarity sensitive, but the two leads need to go back on the same two terminals, and a photo saves you a second trip up the ladder.
  4. Remove the mounting screw and lift the old switch out. Note which way the sail paddle faced — the new switch has to face the same way, with the paddle free to swing into the airflow, not against the housing.
  5. Fit the new switch on the same holes. Set the paddle so it hangs into the air stream and swings freely through its full travel. If the paddle touches the housing or the blower wheel, the switch will never close.
  6. Reconnect the two leads and restore power and gas. Start the thermostat call for heat: the blower runs first, and after the airflow proves out — typically 15 to 30 seconds — the igniter fires and the burner lights.
  7. If it still will not light, check airflow before replacing anything else. Look for a crushed or disconnected duct, a return-air restriction, a blower wheel loaded with dust, and battery voltage below roughly 12 V while the blower runs. All three keep the sail from lifting, and no switch will fix them.

Frequently Asked Questions

Q: Will this 36680 sail switch fit my Atwood Hydro Flame furnace?

A: It fits the furnace models listed in the compatibility table above, and it replaces part numbers 36680, 31377, 35050, 35052, 35054, 35137, 36133 and 37716. Find the model number on the furnace rating plate — usually behind the exterior access panel — and match it against the series table. If the plate shows a number that is not listed, send us a photo of the plate and the old switch and we will confirm before you order.

Q: My furnace ignites and then goes out a few seconds later. Is the sail switch the cause?

A: That is the classic sail switch symptom. The sequence is: blower starts, the igniter clicks, the burner lights, and then the flame drops out because the switch never confirmed airflow and the control board shut the gas valve again. It can also be caused by a dirty flame sensor or a blocked combustion air intake, so the first test is a meter across the switch leads with the blower running — if the contacts never close, the switch or the airflow to it is the problem.

Q: How do I test a sail switch to see if it is bad?

A: Set a multimeter to continuity or resistance and put the probes on the two terminals with the wires disconnected. With the paddle at rest the reading should be open circuit. Push the paddle up by hand and the meter should show continuity. If it stays open when you lift the paddle, or stays closed at rest, the switch has failed. If it tests correctly but the furnace still will not light, the fault is upstream — airflow reaching the switch, the blower, or the control board.

Q: Is 36680 the same part as 31377?

A: Yes. 36680 is the older Atwood number and 31377 is the current Dometic / Atwood service number for the same sail switch. Both numbers, plus 35050, 35052, 35054, 35137, 36133 and 37716, are listed on this switch because they all cross to the same replacement.

Q: What voltage is this switch rated for?

A: The contacts are rated 250 VAC. In the furnace it switches the 12 V DC control circuit that feeds the gas valve and ignition sequence, so the contact rating is well above the load it actually carries. Do not use it as a line-voltage switch for 120 V or 240 V appliances — it is a furnace airflow switch, not a general-purpose power switch.

Q: Can I jumper the sail switch to test whether the furnace will run?

A: Only as a momentary diagnostic, never as a repair. Jumpering the two leads tells the control board that airflow is proven, so the burner will fire even with the blower off or the flue blocked — that is a carbon monoxide and fire risk. If a jumpered furnace lights and an un-jumpered furnace does not, the switch is reporting a real airflow problem. Find the airflow restriction and fix it, then fit this switch and remove the jumper.

Q: The blower runs but there is no heat at all. Is that the sail switch?

A: Sometimes. A sail switch that never closes produces exactly this: blower runs, no ignition, no heat. But the same symptom comes from a failed igniter, a tripped limit switch, a control board that never sends 12 V to the gas valve, or an empty propane tank. The quick discriminator is the igniter: if you hear it clicking and the burner still will not light, airflow and the sail switch are the first things to check; if you hear nothing at all, the fault is more likely electrical, upstream of the switch.

Q: Does the switch come with the bracket and terminals fitted?

A: Yes. The switch arrives as one assembled unit — gray housing, hinged sail paddle, metal mounting bracket and two screw terminals — one switch per pack. It does not include the furnace wiring harness, the gas valve, the igniter or the control board, because those are separate parts of the furnace.

📊 Sail Switch, Limit Switch or Gas Valve — Which One Is Open?

Three different safety devices in the same furnace produce the same "blower runs, no heat" complaint. They are not interchangeable, and replacing the wrong one is the most common wasted repair on an RV furnace.

Device What It Senses Contacts at Rest Typical Symptom When It Fails
Sail switch (36680) Airflow from the blower Open — closes only with air moving Blower runs, igniter clicks, burner lights then dies, or no ignition at all
Limit switch Over-temperature at the heat exchanger Closed — opens when too hot Furnace runs, then shuts down mid-cycle and will not restart until it cools
Gas valve 12 V command from the control board Closed — opens on command Igniter clicks repeatedly with no flame, and you smell no gas at the burner

A sail switch that reads open at rest is normal. A sail switch that reads open with the blower running and the paddle lifted by hand is not — that is the one to replace with this 36680.

📦 Related Products & Guides

🛒 Parts to keep on hand for Atwood RV gas-appliance repairs:

Product Fits Price
93866 Water Heater Thermal Cutoff Switch Kit Atwood RV gas water heaters — the other thermal safety switch in an Atwood gas appliance $23.99
93868 RV Spark & Sensor Electrode Atwood RV water heaters — igniter and flame sense in one part $39.99

Browse more RV parts and generator accessories we stock, or read the cross-reference table below before you order.

🔄 36680 Cross Reference & Fitment Notes

Number / Term What It Is
36680 Atwood sail switch, original part number — the switch this unit replaces
31377 Current Dometic / Atwood service number for the same sail switch
35050 / 35052 / 35054 / 35137 Earlier Hydro Flame sail switch numbers that cross to 36680
36133 / 37716 Intermediate service numbers that cross to 36680
Sail switch Also listed as an airflow switch or "sail" switch — same device, sold by function on some pages
Limit switch Temperature safety device — not interchangeable with this sail switch
Igniter / spark electrode Separate ignition part — replacing it will not fix an airflow fault

Atwood, Hydro Flame and Dometic are trademarks of their respective owners and are referenced here only to identify the furnaces and part numbers this switch fits. This is an iFJF aftermarket sail switch, not a genuine Atwood or Dometic part. It does not include the furnace, the blower, the gas valve, the igniter or the wiring harness.

Not sure your furnace takes a 36680? Send us a photo of the furnace rating plate and the switch you are removing, with the wiring visible. Our team will confirm the match before you order.
Email: support@ifjf.com
Backed by ISO 9001:2015 and IATF 16949:2016 quality management system certifications.

36680 Sail Switch for Atwood Hydro Flame RV Furnace — Replaces 31377

Product form

SKU: FJ-X-SS06-GY

$29.99

      Description

      36680 Sail Switch for Atwood Hydro Flame RV Furnace — Gray, 250 VAC Airflow Safety Switch

      Product Overview

      The iFJF 36680 sail switch is the airflow safety switch that decides whether your Atwood / Hydro Flame RV furnace is allowed to fire. It sits in the blower air stream with a hinged plastic sail: when the blower pushes enough air, the sail lifts, the contacts close and the gas valve opens. When airflow drops — weak blower, blocked duct, low battery — the sail stays down, the contacts stay open and the furnace will not ignite. That is not a fault; it is the switch doing its job before unburned propane can build up in the combustion chamber.

      It is a direct replacement for 36680 (the old Atwood SKU) and 31377 (the current Dometic part number), and it also covers 35050, 35052, 35054, 35137, 36133 and 37716. The switch is rated 250 VAC, uses screw terminals on the original two leads, and mounts on the same bracket holes — no wiring change, no adapter. This listing is the gray version, one switch per pack.

      Key Features

      • Exact 36680 / 31377 Replacement: Same sail shape, same bracket footprint and the same two screw terminals as the switch you are removing — it drops onto the existing mounting holes in the blower compartment.
      • Eight Interchange Numbers Covered: 36680, 31377, 35050, 35052, 35054, 35137, 36133 and 37716 — the full range of Atwood / Hydro Flame part numbers that cross to this switch.
      • 250 VAC Contact Rating: Rated far above the 12 V DC control circuit it actually switches, so the contacts do not pit from the furnace's inductive load.
      • Normally Open, Closes on Airflow: A true airflow-proving switch — the circuit stays open until the blower actually moves air, which is what makes it a safety device and not just a power switch.
      • Hinged Sail Paddle: The paddle hangs from a hinge pin and lifts at a repeatable air velocity, so it does not chatter at low blower speed or stick open after a season of dust.
      • Screw Terminals, Original Lead Positions: Two spade-style screw terminals take the existing leads. Polarity does not matter for the switch function.
      • Gray Glass-Filled Plastic Housing: The molded housing and metal mounting bracket hold their shape in the heat of a furnace compartment, where a soft plastic switch would warp and jam.
      • One Switch Per Pack: Enough to replace the failed switch in a single furnace — no need to buy a two-pack when only one has failed.

      Features & Benefits

      Feature Benefit (What It Means for You)
      Airflow-proving sail paddle The furnace cannot open the gas valve until the blower actually moves air — the exact condition this switch was designed to enforce.
      Crosses to 8 Atwood / Dometic numbers One part covers the older 35050 / 35137 / 37716 furnaces and the current 31377 service number, so you order once instead of guessing which revision your coach was built with.
      250 VAC rated contacts Switching a 12 V DC gas-valve circuit through a 250 V AC rated contact set means the points stay clean far longer than a switch rated only for the load.
      Normally open at rest With the blower off the circuit is open. A no-heat complaint can be traced with a meter at the switch instead of guessing at the control board.
      Same bracket and screw terminals No drilling, no crimping, no new connectors — the swap is a screwdriver job inside the blower compartment.
      Heat-stable gray housing Holds its shape and its sail clearance through repeated heat cycles, so the switch does not start sticking in its second or third season.

      Compatibility & Cross-Reference

      Fits Atwood / Hydro Flame RV furnaces that use the 36680-style sail switch in the blower air stream. Match the model number on your furnace's rating plate against the tables below before ordering.

      Replaces These Part Numbers:

      Part Number Notes
      36680 Original Atwood part number — the number this switch is sold under
      31377 Current Dometic / Atwood service number for the same switch
      35050 Early Hydro Flame furnace sail switch
      35052 Early Hydro Flame furnace sail switch
      35054 Early Hydro Flame furnace sail switch
      35137 Early Hydro Flame furnace sail switch
      36133 Intermediate service number that crosses to 36680
      37716 Intermediate service number that crosses to 36680

      Furnace Models Covered:

      Series Models
      1522 Series 1522 2-Stage, 1522 LD 2-Stage, XT-1522
      2334 / 2540 2334 2-Stage, 2540 2-Stage
      7900 Series 7912-II, 7916-II, 7920-II
      8500 Series II 8516-II, 8520-II, 8525-II, 8531-II, 8535-II; 85-II 16-20, 85-II 31-35
      8500 Series III 8516-III, 8520-III, 8525-III, 8531-III, 8535-III; 85-III 31-35
      8500 Series IV 8516-IV, 8520-IV, 8525-IV, 8531-IV, 8535-IV; 85-IV 16, 85-IV 20, 85-IV 25, 85-IV 31, 85-IV 35
      8900 Series 8935-DC-I, 8935-AC-I, 8940-DC-I, 8940-AC-I, 8935-DC-II, 8935-AC-II, 8940-DC-II, 8940-AC-II, 8935-DC-III, 8935-AC-III, 8940-DC-III, 8940-AC-III
      Do not bypass this switch to "make the furnace run." Jumpering the two leads will fire the burner whether or not the blower is moving air, which is exactly the condition the switch exists to prevent. If a jumpered furnace runs and a furnace with this switch does not, the problem is airflow — a blocked duct, a collapsed flexible hose, a dirty blower wheel or a battery too low to spin the blower at full speed — not a "bad switch." Fix the airflow first, then fit the new switch.

      Specifications

      Specification Value
      Part Number 36680
      Replaces 31377, 35050, 35052, 35054, 35137, 36133, 37716
      Switch Type Sail (airflow-proving) switch, SPST normally open
      Contact Rating 250 VAC
      Circuit Switched Furnace 12 V DC control circuit (gas valve / ignition sequence)
      Actuator Hinged sail paddle on mounting bracket
      Terminals 2 × screw terminals, existing leads reused
      Housing Gray plastic housing with metal mounting bracket
      Mounting Position In the furnace blower air stream, paddle facing airflow
      Dimensions Approx. 2.5 × 0.5 × 0.31 in (64 × 13 × 8 mm)
      Weight Approx. 0.7 oz (20 g)
      Includes 1 × 36680 sail switch (gray)
      Quality iFJF Quality Guarantee

      Installation Tips

      1. Shut the gas off at the cylinder and kill the 12 V feed. Close the propane valve at the tank or at the manifold, then pull the furnace fuse or switch the coach battery disconnect. The blower will still spin on residual power long enough to surprise you.
      2. Open the furnace access panel. On most Atwood / Hydro Flame installations the sail switch sits on the blower housing, downstream of the blower wheel, with two leads running to it. Follow the wires rather than guessing at the part.
      3. Photograph the wiring before you disconnect it. The switch itself is not polarity sensitive, but the two leads need to go back on the same two terminals, and a photo saves you a second trip up the ladder.
      4. Remove the mounting screw and lift the old switch out. Note which way the sail paddle faced — the new switch has to face the same way, with the paddle free to swing into the airflow, not against the housing.
      5. Fit the new switch on the same holes. Set the paddle so it hangs into the air stream and swings freely through its full travel. If the paddle touches the housing or the blower wheel, the switch will never close.
      6. Reconnect the two leads and restore power and gas. Start the thermostat call for heat: the blower runs first, and after the airflow proves out — typically 15 to 30 seconds — the igniter fires and the burner lights.
      7. If it still will not light, check airflow before replacing anything else. Look for a crushed or disconnected duct, a return-air restriction, a blower wheel loaded with dust, and battery voltage below roughly 12 V while the blower runs. All three keep the sail from lifting, and no switch will fix them.

      Frequently Asked Questions

      Q: Will this 36680 sail switch fit my Atwood Hydro Flame furnace?

      A: It fits the furnace models listed in the compatibility table above, and it replaces part numbers 36680, 31377, 35050, 35052, 35054, 35137, 36133 and 37716. Find the model number on the furnace rating plate — usually behind the exterior access panel — and match it against the series table. If the plate shows a number that is not listed, send us a photo of the plate and the old switch and we will confirm before you order.

      Q: My furnace ignites and then goes out a few seconds later. Is the sail switch the cause?

      A: That is the classic sail switch symptom. The sequence is: blower starts, the igniter clicks, the burner lights, and then the flame drops out because the switch never confirmed airflow and the control board shut the gas valve again. It can also be caused by a dirty flame sensor or a blocked combustion air intake, so the first test is a meter across the switch leads with the blower running — if the contacts never close, the switch or the airflow to it is the problem.

      Q: How do I test a sail switch to see if it is bad?

      A: Set a multimeter to continuity or resistance and put the probes on the two terminals with the wires disconnected. With the paddle at rest the reading should be open circuit. Push the paddle up by hand and the meter should show continuity. If it stays open when you lift the paddle, or stays closed at rest, the switch has failed. If it tests correctly but the furnace still will not light, the fault is upstream — airflow reaching the switch, the blower, or the control board.

      Q: Is 36680 the same part as 31377?

      A: Yes. 36680 is the older Atwood number and 31377 is the current Dometic / Atwood service number for the same sail switch. Both numbers, plus 35050, 35052, 35054, 35137, 36133 and 37716, are listed on this switch because they all cross to the same replacement.

      Q: What voltage is this switch rated for?

      A: The contacts are rated 250 VAC. In the furnace it switches the 12 V DC control circuit that feeds the gas valve and ignition sequence, so the contact rating is well above the load it actually carries. Do not use it as a line-voltage switch for 120 V or 240 V appliances — it is a furnace airflow switch, not a general-purpose power switch.

      Q: Can I jumper the sail switch to test whether the furnace will run?

      A: Only as a momentary diagnostic, never as a repair. Jumpering the two leads tells the control board that airflow is proven, so the burner will fire even with the blower off or the flue blocked — that is a carbon monoxide and fire risk. If a jumpered furnace lights and an un-jumpered furnace does not, the switch is reporting a real airflow problem. Find the airflow restriction and fix it, then fit this switch and remove the jumper.

      Q: The blower runs but there is no heat at all. Is that the sail switch?

      A: Sometimes. A sail switch that never closes produces exactly this: blower runs, no ignition, no heat. But the same symptom comes from a failed igniter, a tripped limit switch, a control board that never sends 12 V to the gas valve, or an empty propane tank. The quick discriminator is the igniter: if you hear it clicking and the burner still will not light, airflow and the sail switch are the first things to check; if you hear nothing at all, the fault is more likely electrical, upstream of the switch.

      Q: Does the switch come with the bracket and terminals fitted?

      A: Yes. The switch arrives as one assembled unit — gray housing, hinged sail paddle, metal mounting bracket and two screw terminals — one switch per pack. It does not include the furnace wiring harness, the gas valve, the igniter or the control board, because those are separate parts of the furnace.

      📊 Sail Switch, Limit Switch or Gas Valve — Which One Is Open?

      Three different safety devices in the same furnace produce the same "blower runs, no heat" complaint. They are not interchangeable, and replacing the wrong one is the most common wasted repair on an RV furnace.

      Device What It Senses Contacts at Rest Typical Symptom When It Fails
      Sail switch (36680) Airflow from the blower Open — closes only with air moving Blower runs, igniter clicks, burner lights then dies, or no ignition at all
      Limit switch Over-temperature at the heat exchanger Closed — opens when too hot Furnace runs, then shuts down mid-cycle and will not restart until it cools
      Gas valve 12 V command from the control board Closed — opens on command Igniter clicks repeatedly with no flame, and you smell no gas at the burner

      A sail switch that reads open at rest is normal. A sail switch that reads open with the blower running and the paddle lifted by hand is not — that is the one to replace with this 36680.

      📦 Related Products & Guides

      🛒 Parts to keep on hand for Atwood RV gas-appliance repairs:

      Product Fits Price
      93866 Water Heater Thermal Cutoff Switch Kit Atwood RV gas water heaters — the other thermal safety switch in an Atwood gas appliance $23.99
      93868 RV Spark & Sensor Electrode Atwood RV water heaters — igniter and flame sense in one part $39.99

      Browse more RV parts and generator accessories we stock, or read the cross-reference table below before you order.

      🔄 36680 Cross Reference & Fitment Notes

      Number / Term What It Is
      36680 Atwood sail switch, original part number — the switch this unit replaces
      31377 Current Dometic / Atwood service number for the same sail switch
      35050 / 35052 / 35054 / 35137 Earlier Hydro Flame sail switch numbers that cross to 36680
      36133 / 37716 Intermediate service numbers that cross to 36680
      Sail switch Also listed as an airflow switch or "sail" switch — same device, sold by function on some pages
      Limit switch Temperature safety device — not interchangeable with this sail switch
      Igniter / spark electrode Separate ignition part — replacing it will not fix an airflow fault

      Atwood, Hydro Flame and Dometic are trademarks of their respective owners and are referenced here only to identify the furnaces and part numbers this switch fits. This is an iFJF aftermarket sail switch, not a genuine Atwood or Dometic part. It does not include the furnace, the blower, the gas valve, the igniter or the wiring harness.

      Not sure your furnace takes a 36680? Send us a photo of the furnace rating plate and the switch you are removing, with the wiring visible. Our team will confirm the match before you order.
      Email: support@ifjf.com
      Backed by ISO 9001:2015 and IATF 16949:2016 quality management system certifications.

      Recently viewed products

      © 2026 iFJF Direct | Sitemap

        • American Express
        • Diners Club
        • Discover
        • Maestro
        • Mastercard
        • PayPal
        • Visa

        Login

        Forgot your password?

        Don't have an account yet?
        Create account