Description
31094 RV Furnace Sail Switch for Atwood AFM, AFLA, AFLD & DFMD Series — Gray Airflow Safety Switch
The iFJF 31094 sail switch is the airflow safety switch inside your Atwood / Dometic RV furnace that decides whether the burner is allowed to fire. The switch sits in the blower air stream with a hinged paddle: when the blower reaches roughly 75% of its running speed, the airflow lifts the paddle, the contacts close and the control board opens the gas valve. If the blower is weak, a duct is crushed or the battery is low, the paddle never lifts, the circuit stays open and the furnace refuses to ignite — which is exactly what it is supposed to do before unburned propane can collect in the combustion chamber.
This is a direct replacement for 31094 and the current Dometic service number 36165 (4471008700), and it also covers the older 31094MC, 31093, 33082, 33081 and 33063 switches used on the same furnace families. The microswitch is rated 0.1 A at 125/250 VAC, uses the original screw terminals and bracket holes, and is built for the AFM, AFLA, AFLD and DFMD furnace series built before the serial-number cutoffs listed below. One switch per pack.
Key Features
-
Exact 31094 Fit: Same paddle, same bracket footprint and the same screw terminals as the switch you are removing, so it drops onto the existing mounting holes in the blower compartment.
-
Seven Interchange Numbers Covered: 31094, 31094MC, 31093, 33082, 33081, 33063 and 36165 (Dometic 4471008700) — the full range of Atwood numbers an AFM, AFLA, AFLD or DFMD furnace was built with.
-
0.1 A, 125/250 VAC Microswitch: A genuine airflow-rated microswitch (40T85 temperature class) rather than a generic lever switch pressed into service as a sail switch.
-
Airflow-Proving, Not Just a Power Switch: The COM–NO contact pair stays open until the blower actually moves air, so a failed blower or a blocked duct becomes a no-heat condition instead of a gas leak.
-
Hinged Paddle with Repeatable Trip Point: The paddle swings on a hinge pin and lifts at a consistent air velocity, so it does not chatter at low blower speed or stick open after a season of dust.
-
Three Screw Terminals, Original Wiring Reused: COM, NO and NC terminals — the furnace uses COM and NO, exactly as the factory switch was wired, with no crimping and no adapter harness.
-
Heat-Stable Gray Housing: The molded housing and metal mounting bracket hold their shape and their paddle clearance through repeated heat cycles in the furnace compartment.
-
One Switch Per Pack: Enough to replace the failed switch in a single furnace — you do not have to buy a two-pack when only one has failed.
Features & Benefits
| Feature |
Benefit (What It Means for You) |
| Direct 31094 replacement |
No drilling, no new connectors and no guessing which revision your furnace was built with — the switch mounts on the same bracket holes. |
| Covers 36165 / 4471008700 |
If your parts counter handed you the newer Dometic number — or an older 31093 / 33082 — this is the same switch, so an obsolete listing is no longer a dead end. |
| 0.1 A microswitch, 125/250 VAC |
Rated well above the 12 V DC control circuit it actually switches, so the contacts do not pit from the gas valve's inductive load. |
| Normally open at rest |
With the blower off the circuit is open — a no-heat complaint can be traced with a meter at the switch instead of guessing at the control board. |
| Hinged paddle, stable trip point |
Lifts at the same air velocity every cycle, so the furnace does not short-cycle or drop out mid-heat as the paddle wears in. |
| Serial-number fitment table |
AFM, AFLA, AFLD and DFMD each have their own cutoff, printed below — you can confirm the match from the rating plate before you order. |
Compatibility & Cross-Reference
Fits Atwood / Dometic RV furnaces that use the 31094-style sail switch in the blower air stream. The serial-number cutoffs below come from the manufacturer cross-reference: this switch is listed for furnaces built before those numbers. Check the model and serial on your furnace rating plate — usually behind the exterior access panel — before ordering.
Replaces These Part Numbers:
| Part Number |
Notes |
| 31094 |
Original Atwood part number — the number this switch is sold under |
| 31094MC |
Later MC Enterprises service version of the same sail switch |
| 31093 |
Earlier Atwood service number that crosses to this switch |
| 36165 |
Current Dometic service number (Dometic 4471008700) for this airflow switch |
| 33082 |
Earlier Atwood sail switch number that crosses to this part |
| 33081 |
Earlier Atwood sail switch number that crosses to this part |
| 33063 |
Earlier Atwood sail switch number that crosses to this part |
Furnace Models Covered (serial number cutoffs apply):
| Series |
Serial Number |
Models |
| AFM |
Before 72489156 |
AFMD25111, AFMD25121, AFMD25131, AFMD25141, AFMD25151, AFMD30111, AFMD30121, AFMD30131, AFMD30141, AFMD30151, AFMD35111, AFMD35121, AFMD35131, AFMD35141, AFMD35151 |
| AFLA |
Before 81689155 |
AFLA35211, AFLA35221, AFLA35231, AFLA40211, AFLA40221, AFLA40231 |
| AFLD |
Before 72991127 |
AFLD35111, AFLD35121, AFLD35131, AFLD40111, AFLD40121, AFLD40131 |
| DFMD |
Before 72489156 |
DFMD25111, DFMD25121, DFMD25131, DFMD25141, DFMD25151 |
Match the serial number as well as the model. The cutoffs above are the manufacturer's cross-reference for this switch, so a furnace built after its series cutoff may use a different service switch. The model and serial are both on the rating plate behind the exterior access panel — if the plate is hard to read, send us a photo and we will confirm before you order.
Specifications
| Specification |
Value |
| Part Number |
31094 |
| Replaces |
31094MC, 31093, 36165 (4471008700), 33082, 33081, 33063 |
| Switch Type |
Sail (airflow-proving) microswitch, SPDT wired on NO |
| Contact Rating |
0.1 A at 125/250 VAC |
| Temperature Class |
40T85 (85 °C) |
| Circuit Switched |
Furnace 12 V DC control circuit (gas valve / ignition sequence) |
| Actuator |
Hinged sail paddle on metal mounting bracket |
| Terminals |
3 × screw terminals (COM / NO / NC); furnace uses COM + NO |
| Housing |
Gray plastic housing with metal mounting bracket |
| Mounting Position |
In the furnace blower air stream, paddle facing airflow |
| Overall Dimensions |
Approx. 3.54 × 2.36 × 0.59 in (90 × 60 × 15 mm), bracket included |
| Weight |
Approx. 0.63 oz (18 g) |
| Includes |
1 × 31094 sail switch (gray) |
| Quality |
iFJF Quality Guarantee |
Installation Tips
-
Shut the gas off at the cylinder and kill the 12 V feed. Close the propane valve at the tank or manifold, then pull the furnace fuse or switch the coach battery disconnect. The blower will still spin on residual power long enough to surprise you.
-
Open the furnace access panel and find the blower housing. On Atwood AFM, AFLA, AFLD and DFMD furnaces the sail switch sits on the blower housing with the paddle reaching into the air stream. Follow the wires rather than guessing at the part.
-
Photograph the wiring before you disconnect it. The switch has COM, NO and NC terminals but the furnace only uses COM and NO. A photo of which lead went where saves you a second trip up the ladder.
-
Remove the mounting screw and lift the old switch out. Note which way the paddle faced and how far it reached into the air stream — the new switch has to sit at the same depth, with the paddle free to swing, not rubbing the housing.
-
Compare old and new paddle side by side. Same length, same bend, same mounting ear. If the profile differs, stop and contact us — forcing a mismatched paddle is how furnaces end up with a switch that never closes.
-
Fit the new switch on the same holes and reconnect COM and NO. Leave the NC terminal empty unless your original wiring used it. Restore power and gas, then call for heat: the blower runs first, and after airflow proves out the igniter fires and the burner lights.
-
If it still will not light, check airflow before replacing anything else. Look for a crushed or disconnected duct, a return-air restriction, a blower wheel loaded with dust, and battery voltage below roughly 12 V while the blower runs. All three keep the paddle from lifting, and no switch will fix them.
Frequently Asked Questions
Q: Will this 31094 sail switch fit my Atwood furnace?
A: It fits the AFM, AFLA, AFLD and DFMD models listed in the compatibility table, provided your furnace serial number is below the cutoff for that series (AFM and DFMD before 72489156, AFLA before 81689155, AFLD before 72991127). Find the model and serial on the rating plate behind the exterior access panel and match them against the table. If the plate shows a number that is not listed, send us a photo of the plate and the old switch and we will confirm before you order.
Q: My furnace lights and then goes out a few seconds later. Is the sail switch the cause?
A: That is the classic sail switch symptom. The blower starts, the igniter clicks, the burner lights, and then the flame drops out because the switch never confirmed airflow and the control board shut the gas valve again. A dirty flame sensor or a blocked combustion air intake can produce the same sequence, so the first test is a meter across the COM and NO terminals with the blower running — if the contacts never close, the switch or the airflow reaching it is the problem.
Q: How do I test a sail switch to see if it is bad?
A: Set a multimeter to continuity and put the probes on COM and NO with the wires disconnected. At rest the reading should be open circuit; push the paddle up by hand and it should show continuity. If it stays open when you lift the paddle, or stays closed at rest, the switch has failed. If it tests correctly but the furnace still will not light, the fault is upstream — airflow reaching the switch, the blower, or the control board.
Q: What is the difference between 31094, 31093, 33082 and 36165?
A: They are all sail switches for the same furnace families and all cross to this replacement. 31094 is the original number for these AFM, AFLA, AFLD and DFMD furnaces; 31094MC is the later MC Enterprises service version; 31093, 33082, 33081 and 33063 are earlier Atwood numbers that cross to the same switch; and 36165 (Dometic 4471008700) is the current service number a dealer will hand you today. Whichever of these numbers is on your old switch, this part replaces it.
Q: Why does the switch have three terminals if the furnace only uses two?
A: The microswitch itself is a changeover (SPDT) type with COM, NO and NC contacts. Atwood's furnace wiring uses COM and NO, so the NC terminal stays empty. Do not move a lead onto NC to "make it work" — that inverts the switch logic and the furnace would try to fire with the blower off.
Q: The blower runs but there is no heat at all. Is that the sail switch?
A: Sometimes. A sail switch that never closes gives exactly this: blower runs, no ignition, no heat. But the same symptom comes from a failed igniter, a tripped limit switch, a control board that never sends 12 V to the gas valve, or an empty propane tank. The quick discriminator is the igniter: if you hear it clicking and the burner still will not light, check airflow and the sail switch first; if you hear nothing at all, the fault is more likely electrical, upstream of the switch.
Q: Can I jumper the sail switch to test whether the furnace will run?
A: Only as a momentary diagnostic, never as a repair. Jumpering COM and NO tells the control board that airflow is proven, so the burner will fire even with the blower off or the flue blocked — that is a carbon monoxide and fire risk. If a jumpered furnace lights and an un-jumpered furnace does not, the switch is reporting a real airflow problem. Find the restriction, fix it, then fit this switch and remove the jumper.
Q: Does the switch come with the bracket and terminals fitted?
A: Yes. It arrives as one assembled unit — gray housing, hinged paddle, metal mounting bracket and three screw terminals — one switch per pack. It does not include the furnace wiring harness, the gas valve, the igniter or the control board, because those are separate parts of the furnace.
📊 31094 vs 31093 vs 36165 — Which Sail Switch Does Your Atwood Take?
Four part numbers, one furnace family and a very common mistake: buying the switch that is cheapest instead of the one that matches the furnace on your coach. Use the table to narrow it down, then confirm against the old part.
| Part |
Listed For |
Paddle |
Notes |
|
31094 (this switch) |
AFM, AFLA, AFLD, DFMD before the serial cutoffs above |
Hinged sail, bracket mounted |
Original number; crosses to 31094MC, 31093, 33082, 33081, 33063 and 36165 |
| 31093 |
AFS and AFM furnaces with earlier serials |
Same sail-switch design |
Earlier Atwood number — this switch replaces it |
|
36165 (4471008700) |
Current Dometic service number for the same furnaces |
Same family as 31094 |
What a dealer will sell you today; this switch covers it |
| 36680 |
Atwood Hydro Flame furnaces (7900 / 8500 / 8900 series) |
Different housing and bracket |
A different furnace family — do not substitute it for a 31094 |
A sail switch that reads open at rest is normal. A sail switch that reads open with the blower running and the paddle lifted by hand is not — that is the one to replace with this 31094.
📦 Related Products & Guides
Parts our customers keep on hand for Atwood RV furnace and water heater repairs.
Browse more RV parts and generator accessories we stock, or read the cross-reference table below before you order.
🔄 31094 Cross Reference & Fitment Notes
| Number / Term |
What It Is |
| 31094 |
Atwood sail switch, original part number — the switch this unit replaces |
| 31094MC |
MC Enterprises service version of the same sail switch |
| 36165 / 4471008700 |
Current Dometic service number for this airflow switch |
| 33082 / 33081 / 33063 |
Earlier Atwood sail switch numbers that cross to 31094 |
| 31093 |
Earlier Atwood service number for AFS and AFM furnaces — crosses to this switch |
| Sail switch |
Also listed as an airflow switch or air-proving switch — same device, sold by function on some pages |
| Limit switch |
Temperature safety device — not interchangeable with this sail switch |
| Igniter / spark electrode |
Separate ignition part — replacing it will not fix an airflow fault |
Atwood and Dometic are trademarks of their respective owners and are referenced here only to identify the furnaces and part numbers this switch fits. This is an iFJF aftermarket sail switch, not a genuine Atwood or Dometic part. It does not include the furnace, the blower, the gas valve, the igniter or the wiring harness.
Not sure your furnace takes a 31094? Send us a photo of the furnace rating plate and the switch you are removing, with the paddle and wiring visible. Our team will confirm the match before you order.
Email: support@ifjf.com
Backed by ISO 9001:2015 and IATF 16949:2016 quality management system certifications.