031-01267-001A Furnace Control Board 120V HSI for York Luxaire Coleman

Description

031-01267-001A Furnace Control Board 120V HSI for York Luxaire Coleman

The 031-01267-001A is a single-stage integrated furnace control (IFC) with hot surface ignition for York, Luxaire, Coleman and Evcon gas furnaces — the TG9S, TG8S, TGLS, GG9S, GG8S, GGLS, MG9S, G9T, G8T, G8C, FG8, FG9 and FL8 single-stage series. It replaces the White-Rodgers 50A56 series control — including 50A56-956, 50A56-242 and 50A56-243 — along with the York numbers 265901, 265902, 539617 and the S1-33103010000 / S1-0310 series service parts. One board runs the ignition sequence, watches the flame sensor and safety switches, and drives the inducer, gas valve and a three-speed blower. If your furnace is flashing an LED fault code, blowing cold air or running the blower nonstop, match the number printed on your old board against the cross-reference table below before you order.

📋 Key Takeaways

  • ✅ Cross-reference you can verify: replaces 031-01267-001A, 031-01267-001, P031-01267-001, 031-01972-000, 031-01266-000, 031-01140-702, York 265901 / 265902 / 539617, S1-33103010000 and the S1-0310 / S1-3310 service numbers, White-Rodgers 50A56-956 / 50A56-242 / 50A56-243.
  • ✅ Single-stage hot surface ignition: 120 VAC igniter relay rated 6.0 A, with flame sensing and automatic gas-valve shutoff on any abnormal condition.
  • ✅ Full blower control: heat on delay 30 s, heat off delay selectable at 60 / 90 / 120 / 180 s, cool off delay 60 s, across three speed taps for PSC blower and inducer motors.
  • ✅ Built for two-furnace installs: twinning compatible, with 120 VAC humidifier and electronic air cleaner outputs at up to 1 A each.
  • ✅ Diagnostics on the board: LED flash codes for lockout and sensor faults, plus a replaceable automotive-style fuse that protects the low-voltage transformer from a miswire.
  • ✅ Check the old board first: this is not a universal control — it covers the York / Luxaire / Coleman / Evcon boards listed above, and nothing else.

Features & Benefits

Feature Benefit (What It Means for You)
York 50A56-956 Crossover One board covers the White-Rodgers 50A56-956 / 242 / 243 controls and the York 265901, 265902, 539617 and S1-33103010000 service numbers, so you stop hunting for a discontinued revision.
Microprocessor Ignition Sequence Runs inducer prove, igniter warm-up, gas valve open, flame sense and blower-on in the factory order, and closes the gas valve the moment the flame signal is lost.
120 VAC Igniter Relay, 6.0 A Matched to a 120 V hot surface igniter — the relay rating is stated openly so you can confirm it against the igniter your furnace actually uses.
Selectable Heat-Off Delay Choose 60, 90, 120 or 180 seconds of blower run-on after the burner shuts down, so the last of the warm air reaches the rooms instead of the flue.
Twinning Compatible Two furnaces on one thermostat can run as a pair without adding a separate twinning kit to the job.
LED Flash Codes + Replaceable Fuse The LED tells you which safety circuit opened before you reach for a meter, and the automotive-style fuse is the one field-serviceable part — it takes the hit when wiring is crossed.

Compatibility & Cross-Reference

Replaces / Interchange Part Numbers:

Interchange Part Number System / Brand
031-01267-001A Board number of this replacement
031-01267-001 · P031-01267-001 York (same board, earlier label)
031-01266-000 · 031-01140-702 York earlier revisions
031-01972-000 York / Coleman (current board)
S1-33103010000 York service-part number
S1-33102956000 · S1-03109167000 York service-part numbers
S1-03101267000 · S1-03101267001 York service-part numbers
S1-03101266000 · S1-03101250000 York service-part numbers
S1-03101284000 · S1-03100662000 York service-part numbers
S1-03101933000 · S1-03101972000 York service-part numbers
S1-03101973000 York service-part number
265901 · 265902 · 539617 York short numbers
50A56-956 White-Rodgers (OEM control)
50A56-242 · 50A56-243 White-Rodgers (earlier revisions)
ICM2808 ICM Controls replacement for 50A56-956
1162-202 · 1162-83-202 ICM / aftermarket equivalent
1162-201 · 1162-83-201A ICM / aftermarket earlier revision
L45-088 Johnstone Supply number
031-03010-000 · 331-03010-000 York (same board, other label formats)

Compatible Furnace Series:

York has consolidated 031-01267-001A and 21 other control numbers into a single service part, S1-33103010000. The table below is the fleet that one consolidated board covers — every furnace on it takes this replacement. All are single-stage hot surface ignition units built by York / Johnson Controls and sold under York, Coleman, Luxaire, Evcon and Fraser-Johnston badges:

Series Brand Example Model
TG9S · TG8S · TGLS York · Coleman · Luxaire TG9S080B12MP11 · TGLS080C16MP11
GG9S · GG8S · GGLS · MG9S York · Coleman · Luxaire GG9S060B12MP11 · MG9S080B12MP11
G9T · G8T · G8C · GY8S · GF8 York (upflow / downflow) G9T08016UPC13 · G8C10016MUC12
FG8 · FG9 · FL8 York · Fraser-Johnston FG9C10020UP11 · FL8B10016UH12
RGF1L · RGF19 · PS8E York packaged units RGF1L080BP12MP11 · PS8E30N130UH21

How to confirm fitment: the part number on the old board decides it, not the brand badge on the furnace door. Pull the blower compartment cover, read the number printed on the board, and match it to the cross-reference table above. Boards outside this list — Rheem, Ruud, Carrier, Bryant, Lennox and Trane controls — use a different terminal layout and ignition design, and no adapter wiring makes them interchangeable.

One bracket note: the York consolidated kit S1-33103010000 ships as a kit with a mounting bracket. This replacement is the board on its own and mounts on the standoffs or bracket already inside your cabinet — confirm yours is still there before you order.

Specifications

Part Number 031-01267-001A
Control Type Single-stage integrated furnace control (IFC)
Ignition Hot surface ignition (HSI), 120 VAC igniter
Control Input 25 VAC, 50/60 Hz, 0.45 A maximum
Igniter Relay 6.0 A at 120 VAC (resistive)
Diode Relay 2.2 FLA / 3.5 LRA at 120 VAC
Circulator Relay 14.5 FLA / 25.0 LRA at 120 VAC
Thermostat Terminals R, C, W, G, Y1, Y/Y2 (spade terminals)
Blower Delays Heat on 30 s; heat off 60 / 90 / 120 / 180 s selectable; cool off 60 s
Speed Taps 3 (heat, low cool, high cool) for PSC blower and inducer motors
Accessory Outputs 120 VAC humidifier and electronic air cleaner, 1 A maximum each
Protection Replaceable automotive-style fuse; LED fault-code diagnostics
Twinning Supported
Operating Range -40 °F to 176 °F (-40 °C to 80 °C); 5–93% RH non-condensing
Dimensions 6.97 × 4.76 × 0.8 in (177 × 121 × 20 mm)
Weight 8.3 oz (235 g)
Package Contents 1 × furnace control board, 1 × installation manual

Installation Tips

  1. Kill both supplies. Switch the furnace breaker off and close the gas valve upstream of the burner section before the cover comes off.
  2. Photograph every wire. Take one photo of the terminal block before you disconnect anything — the new board uses the same R / C / W / G / Y1 / Y/Y2 labels, so the photo is your map.
  3. Discharge static first. Touch the bare furnace chassis before handling the board; a spark you cannot feel is enough to damage the microprocessor.
  4. Move wires one at a time. Transfer each wire to the identically labeled terminal instead of pulling the whole harness loose, then recheck that no spade is bent or loose.
  5. Read the LED on startup. Power up and call for heat: a steady sequence with the igniter glowing means the board is running; a repeating flash code points to the safety circuit it names.

Why Choose iFJF?

iFJF supplies furnace control boards factory-direct, so you buy the replacement part instead of the dealership markup. What you can check before you buy:

  • ✅ Cross-reference in the open: every covered number — 031-01267-001A, 50A56-956, 265901, S1-33103010000 and the rest — is listed above, so you can match your old board first.
  • ✅ Electrical ratings published: 25 VAC control input, 6.0 A igniter relay at 120 VAC, circulator relay 14.5 FLA / 25.0 LRA — compare them with the numbers on your original control.
  • ✅ Wiring guidance built in: marked terminals and a photo-first procedure, so a homeowner who is comfortable at the breaker can finish the swap without cutting a single wire.
  • ✅ Factory-direct value: supply straight from the manufacturer keeps the price fair without the dealership or middleman markup.
Safety note: furnace controls should be replaced by a qualified HVAC contractor or licensed electrician. Turn off power and shut off the gas supply before removing the old board, and never exceed the rated voltage. If you are unsure whether this board matches your furnace, message us with the model number of your furnace and the part number printed on the old board before ordering.

Need help identifying the right board? Our support team answers fitment questions before you order — support@ifjf.com.

Frequently Asked Questions

Q: Will this board replace 031-01267-001A in my York furnace?

A: Yes. This is a single-stage hot surface ignition control built to replace 031-01267-001A (also labeled 031-01267-001 and P031-01267-001) in York, Luxaire, Coleman and Evcon gas furnaces. Open the blower compartment, read the number printed on the old board, and match it against the cross-reference table above — that table is the fitment list, not the brand name on the furnace door.

Q: My old board says 50A56-956. Is this the same control?

A: Yes. The White-Rodgers 50A56-956, 50A56-242 and 50A56-243 are the same single-stage HSI control family, and the York numbers 265901, 265902 and 539617 cross to it as well. The S1-33103010000 board sold under the York service-part number is the same part. Any of these numbers on your old board means this replacement drops in.

Q: Is this a 120V board or a 24V board?

A: Both ratings apply, in different places. The control is powered by 25 VAC 50/60 Hz from the furnace transformer (0.45 A maximum), while the igniter relay switches 120 VAC at up to 6.0 A to a 120 V hot surface igniter. That is why it is listed as a 120V ignition board — check that your igniter is the 120 V type before ordering.

Q: How hard is the swap for a DIY homeowner?

A: It is a wire-for-wire job with no cutting. Shut the breaker and the gas valve, photograph the old wiring, then move each wire to the identically marked terminal (R, C, W, G, Y1, Y/Y2) on the new board. Touch the chassis before handling the board to discharge static, and never exceed the rated voltage. If you are not comfortable inside a gas appliance, have a licensed HVAC technician do it.

Q: Will a new board fix a blower that runs nonstop or a furnace with no heat?

A: Only if the control is the failed part. A blower that never stops usually means a welded blower relay on the board, which this replacement fixes. No heat with a flashing LED can also be the igniter, flame sensor, pressure switch or gas valve — read the flash code first, because the same symptoms come from parts that sit outside the board.

Q: What comes in the box?

A: One control board and one installation manual. The manual covers the terminal layout, the ignition sequence and the LED fault codes, so you can identify a lockout or pressure-switch fault without a service call. The board reuses the mounting standoffs or bracket already inside your furnace, so no extra screws are needed.

Q: Is this an OEM York board?

A: No. It is a third-party replacement built to the same electrical specification — single-stage HSI, 25 VAC control input, 120 VAC igniter relay, three blower speed taps, twinning support — and it is not sold as a York or White-Rodgers branded part.

Package Includes

  • 1 × 031-01267-001A single-stage furnace control board
  • 1 × installation manual

Common Problems with Furnace Control Boards — Solved by iFJF

We read the 1-star and 2-star reviews of OEM and aftermarket furnace controls in this category. Here is what owners keep running into — and how this board answers it:

❌ What Owners Complain About ✅ How This Board Addresses It
"It said compatible, but my furnace never fired"
— the #1 cause of returns in this category
→ Fitment by part number, not by brand
The full crossover list and the four furnace brands that use it are stated openly, and the listing tells you the boards it does not replace. Read the number on your old board first.
"My number is not the one in the title"
— usually an earlier revision of the same control
→ The whole revision chain is listed
031-01267-001, 031-01972-000, 031-01266-000, 50A56-242, 50A56-243, 265901 and 265902 all run this board, so an older label on the old control does not block the swap.
"No guidance, afraid of wiring it wrong"
— the most common DIY hesitation
→ Photo-first, one wire at a time
Terminals carry the same R / C / W / G / Y1 / Y/Y2 labels, and the five-step procedure above covers power-down, static discharge and the startup LED check.

Which iFJF Furnace Control Board Fits Your Furnace?

Three single-stage boards, three different furnace families. Match the board number, not the brand badge:

Board Fits Control / Ignition Price
031-01267-001A
this listing
York · Luxaire · Coleman · Evcon
50A56-956 / 265901 / S1-33103010000
25 VAC control
120 VAC HSI
$89.99
50A55-843 White-Rodgers · Lennox
50A50-241 / 50A50-405 / 50A55-486
25 VAC control
120 VAC HSI
$137.99
1012-925C Rheem · Ruud · Weather King
62-24268-01 / -02 / -03 / 62-24192-01
24 VAC control
HSI
$179.99

Still not sure? Send us the part number on your old board and the furnace model number — we answer before you order.

Related Products & Guides

Pairs with this part:

Factory Direct Supply & Wholesale — iFJF is a direct manufacturer of high-performance replacement parts for heating and filtration systems. Custom specifications and bulk orders are highly welcome. Contact us for exclusive dealer pricing and volume discounts. Backed by ISO 9001:2015 and IATF 16949:2016 quality management system certifications.
Email: support@ifjf.com
📖 Related Guide: First Cold Snap, Dead Furnace: Why the 031-01267-001A Board Fails — why this board fails on the first cold snap, how to read the diagnostic LED codes, and how hard the swap is.

031-01267-001A Furnace Control Board 120V HSI for York Luxaire Coleman

Product form

SKU: FJ-CB-0310

$89.99

    • Shipped today? Order within: Nov 22, 2026 17:00:00 +0800

    Description

    031-01267-001A Furnace Control Board 120V HSI for York Luxaire Coleman

    The 031-01267-001A is a single-stage integrated furnace control (IFC) with hot surface ignition for York, Luxaire, Coleman and Evcon gas furnaces — the TG9S, TG8S, TGLS, GG9S, GG8S, GGLS, MG9S, G9T, G8T, G8C, FG8, FG9 and FL8 single-stage series. It replaces the White-Rodgers 50A56 series control — including 50A56-956, 50A56-242 and 50A56-243 — along with the York numbers 265901, 265902, 539617 and the S1-33103010000 / S1-0310 series service parts. One board runs the ignition sequence, watches the flame sensor and safety switches, and drives the inducer, gas valve and a three-speed blower. If your furnace is flashing an LED fault code, blowing cold air or running the blower nonstop, match the number printed on your old board against the cross-reference table below before you order.

    📋 Key Takeaways

    • ✅ Cross-reference you can verify: replaces 031-01267-001A, 031-01267-001, P031-01267-001, 031-01972-000, 031-01266-000, 031-01140-702, York 265901 / 265902 / 539617, S1-33103010000 and the S1-0310 / S1-3310 service numbers, White-Rodgers 50A56-956 / 50A56-242 / 50A56-243.
    • ✅ Single-stage hot surface ignition: 120 VAC igniter relay rated 6.0 A, with flame sensing and automatic gas-valve shutoff on any abnormal condition.
    • ✅ Full blower control: heat on delay 30 s, heat off delay selectable at 60 / 90 / 120 / 180 s, cool off delay 60 s, across three speed taps for PSC blower and inducer motors.
    • ✅ Built for two-furnace installs: twinning compatible, with 120 VAC humidifier and electronic air cleaner outputs at up to 1 A each.
    • ✅ Diagnostics on the board: LED flash codes for lockout and sensor faults, plus a replaceable automotive-style fuse that protects the low-voltage transformer from a miswire.
    • ✅ Check the old board first: this is not a universal control — it covers the York / Luxaire / Coleman / Evcon boards listed above, and nothing else.

    Features & Benefits

    Feature Benefit (What It Means for You)
    York 50A56-956 Crossover One board covers the White-Rodgers 50A56-956 / 242 / 243 controls and the York 265901, 265902, 539617 and S1-33103010000 service numbers, so you stop hunting for a discontinued revision.
    Microprocessor Ignition Sequence Runs inducer prove, igniter warm-up, gas valve open, flame sense and blower-on in the factory order, and closes the gas valve the moment the flame signal is lost.
    120 VAC Igniter Relay, 6.0 A Matched to a 120 V hot surface igniter — the relay rating is stated openly so you can confirm it against the igniter your furnace actually uses.
    Selectable Heat-Off Delay Choose 60, 90, 120 or 180 seconds of blower run-on after the burner shuts down, so the last of the warm air reaches the rooms instead of the flue.
    Twinning Compatible Two furnaces on one thermostat can run as a pair without adding a separate twinning kit to the job.
    LED Flash Codes + Replaceable Fuse The LED tells you which safety circuit opened before you reach for a meter, and the automotive-style fuse is the one field-serviceable part — it takes the hit when wiring is crossed.

    Compatibility & Cross-Reference

    Replaces / Interchange Part Numbers:

    Interchange Part Number System / Brand
    031-01267-001A Board number of this replacement
    031-01267-001 · P031-01267-001 York (same board, earlier label)
    031-01266-000 · 031-01140-702 York earlier revisions
    031-01972-000 York / Coleman (current board)
    S1-33103010000 York service-part number
    S1-33102956000 · S1-03109167000 York service-part numbers
    S1-03101267000 · S1-03101267001 York service-part numbers
    S1-03101266000 · S1-03101250000 York service-part numbers
    S1-03101284000 · S1-03100662000 York service-part numbers
    S1-03101933000 · S1-03101972000 York service-part numbers
    S1-03101973000 York service-part number
    265901 · 265902 · 539617 York short numbers
    50A56-956 White-Rodgers (OEM control)
    50A56-242 · 50A56-243 White-Rodgers (earlier revisions)
    ICM2808 ICM Controls replacement for 50A56-956
    1162-202 · 1162-83-202 ICM / aftermarket equivalent
    1162-201 · 1162-83-201A ICM / aftermarket earlier revision
    L45-088 Johnstone Supply number
    031-03010-000 · 331-03010-000 York (same board, other label formats)

    Compatible Furnace Series:

    York has consolidated 031-01267-001A and 21 other control numbers into a single service part, S1-33103010000. The table below is the fleet that one consolidated board covers — every furnace on it takes this replacement. All are single-stage hot surface ignition units built by York / Johnson Controls and sold under York, Coleman, Luxaire, Evcon and Fraser-Johnston badges:

    Series Brand Example Model
    TG9S · TG8S · TGLS York · Coleman · Luxaire TG9S080B12MP11 · TGLS080C16MP11
    GG9S · GG8S · GGLS · MG9S York · Coleman · Luxaire GG9S060B12MP11 · MG9S080B12MP11
    G9T · G8T · G8C · GY8S · GF8 York (upflow / downflow) G9T08016UPC13 · G8C10016MUC12
    FG8 · FG9 · FL8 York · Fraser-Johnston FG9C10020UP11 · FL8B10016UH12
    RGF1L · RGF19 · PS8E York packaged units RGF1L080BP12MP11 · PS8E30N130UH21

    How to confirm fitment: the part number on the old board decides it, not the brand badge on the furnace door. Pull the blower compartment cover, read the number printed on the board, and match it to the cross-reference table above. Boards outside this list — Rheem, Ruud, Carrier, Bryant, Lennox and Trane controls — use a different terminal layout and ignition design, and no adapter wiring makes them interchangeable.

    One bracket note: the York consolidated kit S1-33103010000 ships as a kit with a mounting bracket. This replacement is the board on its own and mounts on the standoffs or bracket already inside your cabinet — confirm yours is still there before you order.

    Specifications

    Part Number 031-01267-001A
    Control Type Single-stage integrated furnace control (IFC)
    Ignition Hot surface ignition (HSI), 120 VAC igniter
    Control Input 25 VAC, 50/60 Hz, 0.45 A maximum
    Igniter Relay 6.0 A at 120 VAC (resistive)
    Diode Relay 2.2 FLA / 3.5 LRA at 120 VAC
    Circulator Relay 14.5 FLA / 25.0 LRA at 120 VAC
    Thermostat Terminals R, C, W, G, Y1, Y/Y2 (spade terminals)
    Blower Delays Heat on 30 s; heat off 60 / 90 / 120 / 180 s selectable; cool off 60 s
    Speed Taps 3 (heat, low cool, high cool) for PSC blower and inducer motors
    Accessory Outputs 120 VAC humidifier and electronic air cleaner, 1 A maximum each
    Protection Replaceable automotive-style fuse; LED fault-code diagnostics
    Twinning Supported
    Operating Range -40 °F to 176 °F (-40 °C to 80 °C); 5–93% RH non-condensing
    Dimensions 6.97 × 4.76 × 0.8 in (177 × 121 × 20 mm)
    Weight 8.3 oz (235 g)
    Package Contents 1 × furnace control board, 1 × installation manual

    Installation Tips

    1. Kill both supplies. Switch the furnace breaker off and close the gas valve upstream of the burner section before the cover comes off.
    2. Photograph every wire. Take one photo of the terminal block before you disconnect anything — the new board uses the same R / C / W / G / Y1 / Y/Y2 labels, so the photo is your map.
    3. Discharge static first. Touch the bare furnace chassis before handling the board; a spark you cannot feel is enough to damage the microprocessor.
    4. Move wires one at a time. Transfer each wire to the identically labeled terminal instead of pulling the whole harness loose, then recheck that no spade is bent or loose.
    5. Read the LED on startup. Power up and call for heat: a steady sequence with the igniter glowing means the board is running; a repeating flash code points to the safety circuit it names.

    Why Choose iFJF?

    iFJF supplies furnace control boards factory-direct, so you buy the replacement part instead of the dealership markup. What you can check before you buy:

    • ✅ Cross-reference in the open: every covered number — 031-01267-001A, 50A56-956, 265901, S1-33103010000 and the rest — is listed above, so you can match your old board first.
    • ✅ Electrical ratings published: 25 VAC control input, 6.0 A igniter relay at 120 VAC, circulator relay 14.5 FLA / 25.0 LRA — compare them with the numbers on your original control.
    • ✅ Wiring guidance built in: marked terminals and a photo-first procedure, so a homeowner who is comfortable at the breaker can finish the swap without cutting a single wire.
    • ✅ Factory-direct value: supply straight from the manufacturer keeps the price fair without the dealership or middleman markup.
    Safety note: furnace controls should be replaced by a qualified HVAC contractor or licensed electrician. Turn off power and shut off the gas supply before removing the old board, and never exceed the rated voltage. If you are unsure whether this board matches your furnace, message us with the model number of your furnace and the part number printed on the old board before ordering.

    Need help identifying the right board? Our support team answers fitment questions before you order — support@ifjf.com.

    Frequently Asked Questions

    Q: Will this board replace 031-01267-001A in my York furnace?

    A: Yes. This is a single-stage hot surface ignition control built to replace 031-01267-001A (also labeled 031-01267-001 and P031-01267-001) in York, Luxaire, Coleman and Evcon gas furnaces. Open the blower compartment, read the number printed on the old board, and match it against the cross-reference table above — that table is the fitment list, not the brand name on the furnace door.

    Q: My old board says 50A56-956. Is this the same control?

    A: Yes. The White-Rodgers 50A56-956, 50A56-242 and 50A56-243 are the same single-stage HSI control family, and the York numbers 265901, 265902 and 539617 cross to it as well. The S1-33103010000 board sold under the York service-part number is the same part. Any of these numbers on your old board means this replacement drops in.

    Q: Is this a 120V board or a 24V board?

    A: Both ratings apply, in different places. The control is powered by 25 VAC 50/60 Hz from the furnace transformer (0.45 A maximum), while the igniter relay switches 120 VAC at up to 6.0 A to a 120 V hot surface igniter. That is why it is listed as a 120V ignition board — check that your igniter is the 120 V type before ordering.

    Q: How hard is the swap for a DIY homeowner?

    A: It is a wire-for-wire job with no cutting. Shut the breaker and the gas valve, photograph the old wiring, then move each wire to the identically marked terminal (R, C, W, G, Y1, Y/Y2) on the new board. Touch the chassis before handling the board to discharge static, and never exceed the rated voltage. If you are not comfortable inside a gas appliance, have a licensed HVAC technician do it.

    Q: Will a new board fix a blower that runs nonstop or a furnace with no heat?

    A: Only if the control is the failed part. A blower that never stops usually means a welded blower relay on the board, which this replacement fixes. No heat with a flashing LED can also be the igniter, flame sensor, pressure switch or gas valve — read the flash code first, because the same symptoms come from parts that sit outside the board.

    Q: What comes in the box?

    A: One control board and one installation manual. The manual covers the terminal layout, the ignition sequence and the LED fault codes, so you can identify a lockout or pressure-switch fault without a service call. The board reuses the mounting standoffs or bracket already inside your furnace, so no extra screws are needed.

    Q: Is this an OEM York board?

    A: No. It is a third-party replacement built to the same electrical specification — single-stage HSI, 25 VAC control input, 120 VAC igniter relay, three blower speed taps, twinning support — and it is not sold as a York or White-Rodgers branded part.

    Package Includes

    • 1 × 031-01267-001A single-stage furnace control board
    • 1 × installation manual

    Common Problems with Furnace Control Boards — Solved by iFJF

    We read the 1-star and 2-star reviews of OEM and aftermarket furnace controls in this category. Here is what owners keep running into — and how this board answers it:

    ❌ What Owners Complain About ✅ How This Board Addresses It
    "It said compatible, but my furnace never fired"
    — the #1 cause of returns in this category
    → Fitment by part number, not by brand
    The full crossover list and the four furnace brands that use it are stated openly, and the listing tells you the boards it does not replace. Read the number on your old board first.
    "My number is not the one in the title"
    — usually an earlier revision of the same control
    → The whole revision chain is listed
    031-01267-001, 031-01972-000, 031-01266-000, 50A56-242, 50A56-243, 265901 and 265902 all run this board, so an older label on the old control does not block the swap.
    "No guidance, afraid of wiring it wrong"
    — the most common DIY hesitation
    → Photo-first, one wire at a time
    Terminals carry the same R / C / W / G / Y1 / Y/Y2 labels, and the five-step procedure above covers power-down, static discharge and the startup LED check.

    Which iFJF Furnace Control Board Fits Your Furnace?

    Three single-stage boards, three different furnace families. Match the board number, not the brand badge:

    Board Fits Control / Ignition Price
    031-01267-001A
    this listing
    York · Luxaire · Coleman · Evcon
    50A56-956 / 265901 / S1-33103010000
    25 VAC control
    120 VAC HSI
    $89.99
    50A55-843 White-Rodgers · Lennox
    50A50-241 / 50A50-405 / 50A55-486
    25 VAC control
    120 VAC HSI
    $137.99
    1012-925C Rheem · Ruud · Weather King
    62-24268-01 / -02 / -03 / 62-24192-01
    24 VAC control
    HSI
    $179.99

    Still not sure? Send us the part number on your old board and the furnace model number — we answer before you order.

    Related Products & Guides

    Pairs with this part:

    Factory Direct Supply & Wholesale — iFJF is a direct manufacturer of high-performance replacement parts for heating and filtration systems. Custom specifications and bulk orders are highly welcome. Contact us for exclusive dealer pricing and volume discounts. Backed by ISO 9001:2015 and IATF 16949:2016 quality management system certifications.
    Email: support@ifjf.com
    📖 Related Guide: First Cold Snap, Dead Furnace: Why the 031-01267-001A Board Fails — why this board fails on the first cold snap, how to read the diagnostic LED codes, and how hard the swap is.

    Recently viewed products

    © 2026 iFJF Direct | Sitemap

      • American Express
      • Diners Club
      • Discover
      • Maestro
      • Mastercard
      • PayPal
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account