60105 Ignition Control Board for Mr Heater HeatStar MHU HSU Heaters

Description

60105 Ignition Control Board for Mr Heater / HeatStar — 6-Pin Direct Replacement for MHU & HSU Unit Heaters up to 125,000 BTU

The iFJF 60105 is a 6-pin ignition control board for Mr. Heater, HeatStar, Big Maxx and Enerco overhead unit heaters. It is the board sold under Enerco part number 60105, runs on a 24 VAC control circuit, and fits the MHU45 / 50 / 55 / 70 / 75 / 80 / 125 and HSU45 / 50 / 55 / 70 / 75 / 80 / 125 series in both propane (LP) and natural gas (NG) — every unit rated up to 125,000 BTU. It uses the same Molex connector, the same terminal layout and the same mounting posts as the board it replaces, so the swap is a plug-in job with no rewiring.

The board runs the whole light-off sequence: inducer pre-purge, igniter power, gas valve opening, flame proving by rectification, then blower timing. It also watches the safety string — pressure switch, rollout switch, limit — and reports what it finds with fault-code flashes from the on-board LED, which is the fastest way to tell a dead board from an open safety switch. If the blower runs and the burner never lights, or the heater fires and drops out a few seconds later until it locks out, read the flash code before you buy anything.

Key Features

  • One Board, Two Model Families: Covers all Mr. Heater MHU and HeatStar HSU sizes from 45,000 to 125,000 BTU — a single spare covers a whole fleet of garage and workshop heaters.
  • LP and NG, Same Board: The same 60105 runs both the propane and natural gas version of each model. Gas type is set by the orifices and gas valve springs in your heater, not by the board.
  • 6-Pin Molex Interface: The latest 6-pin connector style. It presses onto the factory harness and seats in one orientation — no splicing, no adapter, no field wiring.
  • Flame Proving & Lockout: Proves flame by rectification on every trial for ignition and shuts the gas valve on flame failure instead of letting raw gas into the heat exchanger.
  • Fault-Code LED: Flashes a stored code for the fault it found, so you can separate an open pressure switch or rollout from a failed board before ordering parts.
  • Inducer & Blower Sequencing: Starts the inducer, holds the blower until the cabinet warms, and runs it on after the burner drops out to sweep residual heat.
  • Matching Footprint: Sits on the same four mounting posts with the same terminal positions — about 5.7" × 4.5" × 1.5".
  • Bench-Checked Before Shipping: Every board is inspected before it leaves the warehouse. Backed by iFJF Quality Guarantee · Easy Returns · Wiring Support.

Compatibility / Fitment

Fits Mr. Heater, HeatStar, Big Maxx and Enerco overhead unit heaters. Each size below is covered in both LP and NG versions. Confirm the number on the board you are removing — and check the connector style note under the table — before ordering.
Series Models Covered (LP & NG) Input Rating
Mr. Heater MHU MHU45, MHU50, MHU55, MHU70, MHU75, MHU80, MHU125 45,000 – 125,000 BTU
HeatStar HSU HSU45, HSU50, HSU55, HSU70, HSU75, HSU80, HSU125 45,000 – 125,000 BTU
Big Maxx / Enerco Units of the same platform sold under these labels Up to 125,000 BTU
Mounting Vertical or horizontal overhead installation Garage, workshop, commercial
⚠️ Check your connector before ordering. On some older Mr. Heater and HeatStar units the 6 pins inside the plastic Molex connector were female pins (those boards were made by NOVAR Controls). The 60105 is the newer male-pin board: it will replace a NOVAR board, but only if you also fit the 60104 ignition harness, which is not included. Pull the connector off your old board and look at the pins — if the pins sit inside the board-side socket, send us a photo before you order.

Specifications

Specification Value
Part Number 60105
Component Type Automatic ignition control board (unit heater)
Control Voltage 24 VAC, 50/60 Hz
Connector 6-pin Molex, male pins (newer style)
Fuel Propane (LP) or natural gas (NG) — same board
Fits Input Range Up to 125,000 BTU
Functions Ignition timing, inducer, gas valve, flame rectification, blower delay, safety interlocks
Diagnostics On-board LED fault-code flashes
Board Size Approx. 5.7" × 4.5" × 1.5" (145 × 114 × 38 mm)
Package Weight 12 oz (340 g)
Includes 1 × 60105 ignition control board
Quality iFJF Quality Guarantee

Installation Tips

  1. Kill both supplies. Open the breaker feeding the unit and close the manual gas valve. The 24 VAC control circuit is fed from the transformer inside the heater, so the wall thermostat being off is not enough.
  2. Read the flash code first. Before you pull the old board, power the unit up and count the LED flashes. That code tells you whether the board saw an open pressure switch, a rollout trip or a flame failure — and it is gone once the board is out.
  3. Photograph the connectors. One phone photo of the old board with the 6-pin harness and every spade lead in place saves more time than any wiring diagram.
  4. Check the pin style. Male pins on the board side accept the standard harness. If the old board had female pins in the connector (NOVAR style), you need the 60104 harness — stop and order it rather than forcing the connector.
  5. Never force the Molex plug. The 6-pin connector only seats one way. If it resists, the pins are misaligned by one position — pull it off and look before pushing harder.
  6. Move the spade leads one at a time. Transfer each lead from the old board to the matching terminal before starting the next, instead of pulling them all off first.
  7. Watch the first cycle. Inducer starts → igniter glows → gas valve opens → burners light → blower starts after the delay. If the burner lights and drops out within seconds, clean the flame sensor and check the pressure switch tubing before blaming the new board.

Frequently Asked Questions

Q: What part number is this board and what does it replace?

A: It is the 60105 ignition control board, the Enerco part number used across Mr. Heater, HeatStar, Big Maxx and Enerco overhead unit heaters. The same board is sold under those brand labels, so 60105 is the number to match. Compare it with the number printed on the board you are removing, and check that your heater has the newer 6-pin male-pin connector before ordering.

Q: Which Mr. Heater and HeatStar heaters use the 60105 board?

A: The Mr. Heater MHU series (MHU45, MHU50, MHU55, MHU70, MHU75, MHU80, MHU125) and the HeatStar HSU series (HSU45, HSU50, HSU55, HSU70, HSU75, HSU80, HSU125), in both propane and natural gas versions. Every model in that range is rated up to 125,000 BTU. Because the same board is shared across the whole family, the part number on your old board is the reliable check, not the model badge alone.

Q: How do I tell the newer 6-pin board from the older NOVAR board?

A: Pull the 6-pin Molex connector off the old board and look at the pins. On the newer style the pins stand up on the board and go into the harness plug. On the older NOVAR boards the pins were female and sat inside the board-side connector, and those boards were marked near the Y C W G R screw terminals. A 60105 will replace a NOVAR board, but you also need the 60104 ignition harness, which is not included. Send us a photo of the connector if you are unsure.

Q: My blower runs but the burner never lights. Is the board bad?

A: Not necessarily - read the LED flash code before buying anything. A blinking code points at a specific fault: a pressure switch that never closes (blocked tubing, water in the hose, blocked flue), a rollout switch that tripped, a limit that opened, or a flame that failed to prove. Clean the flame sensor and check the pressure switch tubing first, since both produce the same no-heat symptom as a dead board. If the code says ignition failure and the igniter does not glow, or the heater locks out immediately after the gas valve should open, the board is the usual cause.

Q: Does the 60105 work on both propane and natural gas heaters?

A: Yes. It is the same board for the LP and NG version of each model. The fuel type is set by the orifices and gas valve springs in the heater, not by the control board, so you do not need a separate part number for propane.

Q: Is this a genuine Enerco board or an aftermarket replacement?

A: It is an iFJF aftermarket replacement built to the same fitment and function as the factory board. Mr. Heater, HeatStar, Big Maxx and Enerco part numbers are referenced for identification only and remain the property of their owners. It is covered by the iFJF Quality Guarantee, with Easy Returns and Wiring Support if the connector does not line up.

📊 iFJF 60105 vs the Factory Board

Same footprint, same connector, same sequence. The difference is where you buy it and how fast you can get a spare back into a cold shop.

Feature Factory Enerco Board iFJF 60105
Part number 60105 60105 (direct cross)
Connector 6-pin Molex, male pins 6-pin Molex, male pins
Control voltage 24 VAC 24 VAC
Model coverage MHU / HSU 45–125, LP and NG MHU / HSU 45–125, LP and NG
Fault diagnostics LED flash codes LED flash codes
Mounting Factory posts Factory posts, no drilling
Buying channel HVAC / hearth dealer, often special order Order direct, in stock and ready to ship

📦 Related Products & Guides

Heating a shop or a house? These are the control boards our customers compare with the 60105 most often.

Product Fits Price
94W83 Furnace Control Board Lennox gas furnaces — replaces 103085-02 / -03 $93.99
903429 Furnace Control Board Nordyne / Intertherm M1M furnaces $89.99
031-01267-001A Furnace Control Board York, Luxaire & Coleman 120 V HSI furnaces $89.99
50A55-843 Furnace Control Board Lennox & White-Rodgers gas furnaces $137.99

Browse the full range of HVAC control boards and electronics, or see every home & garden heating part we stock.

🔄 60105 Cross Reference & Old-Board Notes

Number What It Is
60105 Enerco ignition control board — iFJF equivalent
60104 Ignition wire harness — only needed when replacing an older NOVAR board, not included
MHU45 – MHU125 Mr. Heater overhead unit heaters using the 60105 board
HSU45 – HSU125 HeatStar overhead unit heaters using the 60105 board

The 60105 is sold under the Mr. Heater, HeatStar, Big Maxx and Enerco labels — the part number is the same across all of them. Brand and part numbers are listed for identification only. The 60105 is an ignition control board: it does not include the blower, the gas valve, the igniter or the 60104 harness.

Not sure which board your heater has? Send us a photo of the existing board with the part number visible, a photo of the 6-pin connector showing the pins, and the model and serial numbers from the rating plate. Our team will confirm the match before you order.
Email: support@ifjf.com
Backed by ISO 9001:2015 and IATF 16949:2016 quality management system certifications.

60105 Ignition Control Board for Mr Heater HeatStar MHU HSU Heaters

Product form

SKU: FJ-CB-60105

$79.99

      Description

      60105 Ignition Control Board for Mr Heater / HeatStar — 6-Pin Direct Replacement for MHU & HSU Unit Heaters up to 125,000 BTU

      The iFJF 60105 is a 6-pin ignition control board for Mr. Heater, HeatStar, Big Maxx and Enerco overhead unit heaters. It is the board sold under Enerco part number 60105, runs on a 24 VAC control circuit, and fits the MHU45 / 50 / 55 / 70 / 75 / 80 / 125 and HSU45 / 50 / 55 / 70 / 75 / 80 / 125 series in both propane (LP) and natural gas (NG) — every unit rated up to 125,000 BTU. It uses the same Molex connector, the same terminal layout and the same mounting posts as the board it replaces, so the swap is a plug-in job with no rewiring.

      The board runs the whole light-off sequence: inducer pre-purge, igniter power, gas valve opening, flame proving by rectification, then blower timing. It also watches the safety string — pressure switch, rollout switch, limit — and reports what it finds with fault-code flashes from the on-board LED, which is the fastest way to tell a dead board from an open safety switch. If the blower runs and the burner never lights, or the heater fires and drops out a few seconds later until it locks out, read the flash code before you buy anything.

      Key Features

      • One Board, Two Model Families: Covers all Mr. Heater MHU and HeatStar HSU sizes from 45,000 to 125,000 BTU — a single spare covers a whole fleet of garage and workshop heaters.
      • LP and NG, Same Board: The same 60105 runs both the propane and natural gas version of each model. Gas type is set by the orifices and gas valve springs in your heater, not by the board.
      • 6-Pin Molex Interface: The latest 6-pin connector style. It presses onto the factory harness and seats in one orientation — no splicing, no adapter, no field wiring.
      • Flame Proving & Lockout: Proves flame by rectification on every trial for ignition and shuts the gas valve on flame failure instead of letting raw gas into the heat exchanger.
      • Fault-Code LED: Flashes a stored code for the fault it found, so you can separate an open pressure switch or rollout from a failed board before ordering parts.
      • Inducer & Blower Sequencing: Starts the inducer, holds the blower until the cabinet warms, and runs it on after the burner drops out to sweep residual heat.
      • Matching Footprint: Sits on the same four mounting posts with the same terminal positions — about 5.7" × 4.5" × 1.5".
      • Bench-Checked Before Shipping: Every board is inspected before it leaves the warehouse. Backed by iFJF Quality Guarantee · Easy Returns · Wiring Support.

      Compatibility / Fitment

      Fits Mr. Heater, HeatStar, Big Maxx and Enerco overhead unit heaters. Each size below is covered in both LP and NG versions. Confirm the number on the board you are removing — and check the connector style note under the table — before ordering.
      Series Models Covered (LP & NG) Input Rating
      Mr. Heater MHU MHU45, MHU50, MHU55, MHU70, MHU75, MHU80, MHU125 45,000 – 125,000 BTU
      HeatStar HSU HSU45, HSU50, HSU55, HSU70, HSU75, HSU80, HSU125 45,000 – 125,000 BTU
      Big Maxx / Enerco Units of the same platform sold under these labels Up to 125,000 BTU
      Mounting Vertical or horizontal overhead installation Garage, workshop, commercial
      ⚠️ Check your connector before ordering. On some older Mr. Heater and HeatStar units the 6 pins inside the plastic Molex connector were female pins (those boards were made by NOVAR Controls). The 60105 is the newer male-pin board: it will replace a NOVAR board, but only if you also fit the 60104 ignition harness, which is not included. Pull the connector off your old board and look at the pins — if the pins sit inside the board-side socket, send us a photo before you order.

      Specifications

      Specification Value
      Part Number 60105
      Component Type Automatic ignition control board (unit heater)
      Control Voltage 24 VAC, 50/60 Hz
      Connector 6-pin Molex, male pins (newer style)
      Fuel Propane (LP) or natural gas (NG) — same board
      Fits Input Range Up to 125,000 BTU
      Functions Ignition timing, inducer, gas valve, flame rectification, blower delay, safety interlocks
      Diagnostics On-board LED fault-code flashes
      Board Size Approx. 5.7" × 4.5" × 1.5" (145 × 114 × 38 mm)
      Package Weight 12 oz (340 g)
      Includes 1 × 60105 ignition control board
      Quality iFJF Quality Guarantee

      Installation Tips

      1. Kill both supplies. Open the breaker feeding the unit and close the manual gas valve. The 24 VAC control circuit is fed from the transformer inside the heater, so the wall thermostat being off is not enough.
      2. Read the flash code first. Before you pull the old board, power the unit up and count the LED flashes. That code tells you whether the board saw an open pressure switch, a rollout trip or a flame failure — and it is gone once the board is out.
      3. Photograph the connectors. One phone photo of the old board with the 6-pin harness and every spade lead in place saves more time than any wiring diagram.
      4. Check the pin style. Male pins on the board side accept the standard harness. If the old board had female pins in the connector (NOVAR style), you need the 60104 harness — stop and order it rather than forcing the connector.
      5. Never force the Molex plug. The 6-pin connector only seats one way. If it resists, the pins are misaligned by one position — pull it off and look before pushing harder.
      6. Move the spade leads one at a time. Transfer each lead from the old board to the matching terminal before starting the next, instead of pulling them all off first.
      7. Watch the first cycle. Inducer starts → igniter glows → gas valve opens → burners light → blower starts after the delay. If the burner lights and drops out within seconds, clean the flame sensor and check the pressure switch tubing before blaming the new board.

      Frequently Asked Questions

      Q: What part number is this board and what does it replace?

      A: It is the 60105 ignition control board, the Enerco part number used across Mr. Heater, HeatStar, Big Maxx and Enerco overhead unit heaters. The same board is sold under those brand labels, so 60105 is the number to match. Compare it with the number printed on the board you are removing, and check that your heater has the newer 6-pin male-pin connector before ordering.

      Q: Which Mr. Heater and HeatStar heaters use the 60105 board?

      A: The Mr. Heater MHU series (MHU45, MHU50, MHU55, MHU70, MHU75, MHU80, MHU125) and the HeatStar HSU series (HSU45, HSU50, HSU55, HSU70, HSU75, HSU80, HSU125), in both propane and natural gas versions. Every model in that range is rated up to 125,000 BTU. Because the same board is shared across the whole family, the part number on your old board is the reliable check, not the model badge alone.

      Q: How do I tell the newer 6-pin board from the older NOVAR board?

      A: Pull the 6-pin Molex connector off the old board and look at the pins. On the newer style the pins stand up on the board and go into the harness plug. On the older NOVAR boards the pins were female and sat inside the board-side connector, and those boards were marked near the Y C W G R screw terminals. A 60105 will replace a NOVAR board, but you also need the 60104 ignition harness, which is not included. Send us a photo of the connector if you are unsure.

      Q: My blower runs but the burner never lights. Is the board bad?

      A: Not necessarily - read the LED flash code before buying anything. A blinking code points at a specific fault: a pressure switch that never closes (blocked tubing, water in the hose, blocked flue), a rollout switch that tripped, a limit that opened, or a flame that failed to prove. Clean the flame sensor and check the pressure switch tubing first, since both produce the same no-heat symptom as a dead board. If the code says ignition failure and the igniter does not glow, or the heater locks out immediately after the gas valve should open, the board is the usual cause.

      Q: Does the 60105 work on both propane and natural gas heaters?

      A: Yes. It is the same board for the LP and NG version of each model. The fuel type is set by the orifices and gas valve springs in the heater, not by the control board, so you do not need a separate part number for propane.

      Q: Is this a genuine Enerco board or an aftermarket replacement?

      A: It is an iFJF aftermarket replacement built to the same fitment and function as the factory board. Mr. Heater, HeatStar, Big Maxx and Enerco part numbers are referenced for identification only and remain the property of their owners. It is covered by the iFJF Quality Guarantee, with Easy Returns and Wiring Support if the connector does not line up.

      📊 iFJF 60105 vs the Factory Board

      Same footprint, same connector, same sequence. The difference is where you buy it and how fast you can get a spare back into a cold shop.

      Feature Factory Enerco Board iFJF 60105
      Part number 60105 60105 (direct cross)
      Connector 6-pin Molex, male pins 6-pin Molex, male pins
      Control voltage 24 VAC 24 VAC
      Model coverage MHU / HSU 45–125, LP and NG MHU / HSU 45–125, LP and NG
      Fault diagnostics LED flash codes LED flash codes
      Mounting Factory posts Factory posts, no drilling
      Buying channel HVAC / hearth dealer, often special order Order direct, in stock and ready to ship

      📦 Related Products & Guides

      Heating a shop or a house? These are the control boards our customers compare with the 60105 most often.

      Product Fits Price
      94W83 Furnace Control Board Lennox gas furnaces — replaces 103085-02 / -03 $93.99
      903429 Furnace Control Board Nordyne / Intertherm M1M furnaces $89.99
      031-01267-001A Furnace Control Board York, Luxaire & Coleman 120 V HSI furnaces $89.99
      50A55-843 Furnace Control Board Lennox & White-Rodgers gas furnaces $137.99

      Browse the full range of HVAC control boards and electronics, or see every home & garden heating part we stock.

      🔄 60105 Cross Reference & Old-Board Notes

      Number What It Is
      60105 Enerco ignition control board — iFJF equivalent
      60104 Ignition wire harness — only needed when replacing an older NOVAR board, not included
      MHU45 – MHU125 Mr. Heater overhead unit heaters using the 60105 board
      HSU45 – HSU125 HeatStar overhead unit heaters using the 60105 board

      The 60105 is sold under the Mr. Heater, HeatStar, Big Maxx and Enerco labels — the part number is the same across all of them. Brand and part numbers are listed for identification only. The 60105 is an ignition control board: it does not include the blower, the gas valve, the igniter or the 60104 harness.

      Not sure which board your heater has? Send us a photo of the existing board with the part number visible, a photo of the 6-pin connector showing the pins, and the model and serial numbers from the rating plate. Our team will confirm the match before you order.
      Email: support@ifjf.com
      Backed by ISO 9001:2015 and IATF 16949:2016 quality management system certifications.

      Recently viewed products

      © 2026 iFJF Direct | Sitemap

        • American Express
        • Diners Club
        • Discover
        • Maestro
        • Mastercard
        • PayPal
        • Visa

        Login

        Forgot your password?

        Don't have an account yet?
        Create account